1. Power ON/OFF Switch
2. Green LED - Power Output Status
3. Red LED - Over Load
4. Red LED - Over Temperature
5. “Schuko” Type AC Outlets
6. Cooling Fans
7. Grounding Terminal
8. DC Input “-”
9. DC Input “+”
10. Remote Control Jack
I
O
6
6
8
9
7
6
4
3
2
1
10
OUTPUT
230V
50Hz
Pure Sine Wave Inverter
Remote
OVER
OVER POWER
TEMP
LOAD
ON
OFF
PST-150S, PST-200S: Front
PST-150S, PST-200S: Back
PST-150S-230 & PST-200S-230: Layout
NEG -
POS +
Fig. 6.3: Layout of PST-150S-12E, PST--150S-24E, PST-200S-12E, PST--200S-24E
seCtIOn 6 |
layout
Lead-acidbatteriescanbecategorizedbythetypeofapplication:
1. Automotiveservice-Starting/Lighting/Ignition(SLI,a.k.a.cranking),and
2. Deepcycleservice.
DeepCycleLeadAcidBatteriesofappropriatecapacityarerecommendedforthese
inverters.
Deep cycle Lead Acid Batteries
Deepcyclebatteriesaredesignedwiththick-plateelectrodestoserveasprimarypower
sources,tohaveaconstantdischargerate,tohavethecapabilitytobedeeplydis-
chargedupto80%capacityandtorepeatedlyacceptrecharging.Theyaremarketed
foruseinrecreationvehicles(RV),boatsandelectricgolfcarts–sotheymaybereferred
toasRVbatteries,marinebatteriesorgolfcartbatteries.UseDeepCyclebatteriesfor
powering these inverters.
Rated capacity in Ampere-hour (Ah)
Batterycapacity“C”isspecifiedinAmpere-hours(Ah).AnAmpereistheunitofmeas-
urementforelectricalcurrentandisdefinedasaCoulombofchargepassingthrough
seCtIOn 7 |
General Information on Batteries for