Servend SV-200 SCI Installation, Use & Care Manual - page 31
Section 3
Operation
Part Number 020003997
4/12
3-7
Programming Modes
SELECTABLE ICE NON-ADJUSTABLE AGITATION
On units equipped with the selectable ice option, timed
agitation for the unit is handled by the control board and is
not adjustable.
NOTE: This timer is re-settable, timed agitation every 3.5 hours
from last dispense or when the power supply is broken.
CRUSHED OR CUBED DEFAULT
This selectable ice option will allow the unit to always default to
either cube or crushed ice or remain at the last selection. This
only applies to control boards 020000875 Rev 7 and up.
How to set default ice dispense setting
CUBED DEFAULT
1. Power on the unit by plugging in receptacle and holding
the cube button at the same time, cube will flash 2 times.
Unit will now change to cube 10 seconds after crush is
selected and/or used.
CRUSHED DEFAULT
2. Power on the unit by plugging in receptacle and holding
the crushed button at the same time, crush will flash 2
times. Unit will now change to crush 10 seconds after
cube is selected and/or used.
LAST SELECTION DEFAULT
3. Power on the unit by plugging in receptacle and holding
cube and crush at the same time, cube and crush will flash
2 times. Unit will now remain in selection of last request.
NOTE: If power is lost to the unit and then powered up
again the unit will retain the last setting and not return to
factory settings.
AGITATION TIMER OPERATIONAL CHECK
Selectable Ice Modules have a Selectable (crushed & cubed)
ice agitation timer test mode:
1. Press and hold “cubed” for over 1 second.
2. While holding “cubed”, press “crushed” three (3) times,
all led's will flash indicating test mode.
3. While in the test mode, the agitator motor will cycle three
(3) times, 3 seconds ON and 10 seconds OFF.
4. After the test mode is complete the unit will
automatically reset to the run mode.
NOTE: To disable the test mode before the three (3) cycles
are complete, press the “cubed” button.
FLAVOR MAGIC MODES
For Units With This Option
The program mode can only be accessed by pressing the
program button during the first five seconds of initial power
up. To exit the program mode at any time hold the program
button for >3 seconds and the controller will switch to the
dispense mode.
PROGRAM DISPENSE TIME
1. The program mode is used to adjust the dispense time. To
access the Program Mode, disconnect power to the control
board, wait ten (10) seconds and reconnect power.
2. Press the program button one time on the control board
during the first five (5) seconds after power is applied.
3. The LED display will show “P r o”. To check the current
dispense time, press the corresponding flavor button on
the touchpad and the time will be displayed on the LED
(Example “1.0”). a. To increase the time (+) by two-
tenths (0.2) second increments press flavor button 1 (far
left button). To decrease the time (-) by two-tenths (0.2)
second increments press flavor button 3 (far right
button). The default setting is one (1.0) second.
PURGE / SANITIZE
1. Purge/Sanitize mode allows the user to purge air from
the syrup lines during initial start-up. The second
function of this mode is to energize the valves to move
sanitizer through all syrup lines automatically.
2. Enter the Purge/Sanitize Mode by press the program
button until “P – S” is displayed.
3. Pressing flavor button 1 (far left button) will activate a
sequenced four (4) second dispense that starts with
flavor 1 then to flavor 2 etc. The valves will continue to
cycle for 15 minutes or until the program button is
pressed once.
PROGRAM
BUTTON
LED
DISPLAY