SVS MINI 5 LIFT Installation Manual - page 10
LIFT SPECIFICATIONS
USA
INTERNATIONAL
VOLTAGE
110V/60HZ
220V/50HZ
LOW VOLTAGE CONTROLLER
24v/ac
24v/ac.
CURRENT DRAW
2.3 amps
2.3 amps/1.2 amps
MATERIAL
Steel/Aluminum
Steel/Aluminum
Power Requirements:
110v/50-60hz -220v/50-60hz
Low Voltage Controller:
Supplied with the lift. 12 pin connector plug. 75' of
Cable (22 gauge/9 conductor).
WHEN USING A TOUCH SCREEN CONTROLLER:
If an external controller is to be used (AMX, Crestron), please refer to the following wiring instructions
-see figure 8.
INSTRUCTIONS:
- Program a release of relays to stop on up and down positions.
- Program a time out after the normal run time, 1 or 2 seconds max.
1. Program an exclusive lockout on up and down so both positions cannot be activated at the same time.
2. Hold relays on to move the lift and release relays to stop the lift -always time out or release relay after
normal use. IMPORTANT: Never leave voltage on the up and down.
Always release voltage
immediately after the travel time has been achieved.
Wiring using Touch Screen Controller
(Figure 8).
IF USING ANY OTHER SYSTEMS, PLEASE CONTACT SVS FOR PROPER WIRING TO AVOID UNSAFE
OPERATIONS.
S V S M I N I 5 L I F T I N S T A L L A T I O N
P a g e 1 0 o f 1 3
(SHOW)
+
-
(SERVICE)
C
2
1
GRN
RED
(
VIEWED FROM BACK)
PUR
BLK
BLU
ORN
GRN
MOTOR
POWER ON
SHOW-OFF-SERVICE
RP2
24VAC
UP
DOWN
BRN
BRN
T O U C H S C R E E N
R E L A Y T W O
T O U C H S C R E E N
R E L A Y O N E
I N S T A L L K E Y S W I T C H I N
R A C K W I T H C O N T R O L P A N E L .
RED
ORN
BLK
GRN
WHT
WHT
BRN
BRN
YEL
BLK
GRN
3
2
1
4
5
6
9
8
7
12
11
10
Terminal Strip
(on newer lifts)