Summary of TB8100

  • Page 1

    Tb8100 base station installation guide mba-00009-06 issue 6 june 2005.

  • Page 2: Contents

    2 tb8100 installation guide © tait electronics limited june 2005 contents 1 installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 personal safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 3: Installation

    Tb8100 installation guide installation 3 © tait electronics limited june 2005 1 installation this chapter describes how to install the tb8100 bss in a standard 19 inch rack or cabinet. It also provides some general information on safety precautions and site requirements. We recommend that you read t...

  • Page 4: 1.2

    4 installation tb8100 installation guide © tait electronics limited june 2005 1.1.3 proximity to rf transmissions do not operate the transmitter when someone is standing within 90 cm (3 ft) of the antenna. Do not operate the transmitter unless you have checked that all rf connectors are secure. 1.1....

  • Page 5: 1.3

    Tb8100 installation guide installation 5 © tait electronics limited june 2005 1.2.2 antenna load important the pa may be damaged if the load is removed or switched while the pa is transmitting. To protect the pa output stage from load transients (i.E. Switching or removing the load), we recommend th...

  • Page 6: 1.4

    6 installation tb8100 installation guide © tait electronics limited june 2005 1.3.4 health, safety and electromagnetic compatibility in europe in the european community, radio and telecommunications equipment is regulated by directive 1999/5/ec, also known as the radio and telecommunications termina...

  • Page 7: 1.5

    Tb8100 installation guide installation 7 © tait electronics limited june 2005 1.5 grounding and lightning protection 1.5.1 electrical ground the tb8100 bss modules are grounded by physical contact between the module case and the subrack. To ensure a good ground connection you must tighten each modul...

  • Page 8: 1.7

    8 installation tb8100 installation guide © tait electronics limited june 2005 1.7 ventilation always ensure there is adequate ventilation around the tb8100 bss. Do not operate it in a sealed cabinet. You must keep the ambient temperature within the specified range, and we strongly recommended that y...

  • Page 9

    Tb8100 installation guide installation 9 © tait electronics limited june 2005 figure 1.2 typical cabinet ventilation requirements b ventilation slots d airflow entry c blanking panels e airflow exit 20cm (8in) 2u ≥ 17.5cm ( ≥ 7in) side view front view top view c c d e b c c.

  • Page 10

    10 installation tb8100 installation guide © tait electronics limited june 2005 to allow enough cooling airflow through a cabinet-mounted bss, we recommend the following: ■ an area of at least 150 cm 2 (23in 2 ) of unrestricted ventilation slots or holes in front of the air intakes for the fans for e...

  • Page 11: 1.8

    Tb8100 installation guide installation 11 © tait electronics limited june 2005 1.8 installing the base station system caution a tb8100 subrack complete with modules can weigh up to 28kg (62 lb), or up to 30kg (66lb) com- plete with packaging. We recommend that, once the equipment is out of the carto...

  • Page 12

    12 installation tb8100 installation guide © tait electronics limited june 2005 3. Slide the carton upwards over the foam cushions and lift it away e . Remove the cushion from the bottom of the bss f . 4. Rotate the bss and cushion carefully over the rear of the bss g so that the bss is the right way...

  • Page 13

    Tb8100 installation guide installation 13 © tait electronics limited june 2005 1. Remove the front panel by undoing the fasteners with a quarter turn anti-clockwise, as described in “replacing modules” in the installation and operation manual. 2. Fit the subrack into the cabinet or rack and secure i...

  • Page 14

    14 installation tb8100 installation guide © tait electronics limited june 2005 1.8.4 optional slide mounting rails you can also use tba2141 slide mounting rails b when mounting the tb8100 bss in a cabinet, as shown in figure 1.6 below. These rails will support the bss while you slide it into the cab...

  • Page 15

    Tb8100 installation guide installation 15 © tait electronics limited june 2005 figure 1.7 below shows two recommended methods of securing these cables to prevent straining either set of terminals. Figure 1.7 dc power cabling secure the cables to the cabinet to support their weight.

  • Page 16: Connection

    16 connection tb8100 installation guide © tait electronics limited june 2005 2 connection 2.1 auxiliary power supply connections pmu auxiliary dc output the pmu can provide an auxiliary dc output when it is fitted with the optional auxiliary power supply board. This board is available with an output...

  • Page 17

    Tb8100 installation guide connection 17 © tait electronics limited june 2005 it is, however, acceptable to connect two or more auxiliary power supply boards in parallel (e.G. For redundancy), as long as the current consumption of the external equipment is less than the rating of one board. This mean...

  • Page 18: 2.2

    18 connection tb8100 installation guide © tait electronics limited june 2005 reciter auxiliary dc input from pmu the system interface board in the reciter has an auxiliary dc input connector. Dc from the auxiliary dc output on the pmu can be supplied to the +aux_v pin on the system interface connect...

  • Page 19

    Tb8100 installation guide connection 19 © tait electronics limited june 2005 the rear of the pa. Connect the other end to the auxiliary dc input connector d at the rear of the reciter. Note if you are using an older reciter with a 4-way connector, you will need to use method 2. 2. On the d-range plu...

  • Page 20: 2.3

    20 connection tb8100 installation guide © tait electronics limited june 2005 2.3 system connections standard the standard system interface board is fitted to reciters bearing the product code tba4xxx-0a0x. If purchased separately, it has the product code tba10a0. It provides the following: it is fit...

  • Page 21

    Tb8100 installation guide connection 21 © tait electronics limited june 2005 isolated this system interface board is fitted to reciters bearing the product code tba4xxx-0b0x or tba5xxx-0b0x. If purchased separately, it has the product code tba10b0. It is the same as the standard model, except that t...

  • Page 22

    22 connection tb8100 installation guide © tait electronics limited june 2005 isolated e&m this system interface board is fitted to reciters bearing the product code tba4xxx-0c0x or tba5xxx-0c0x. If purchased separately, it has the product code tba10c0. It provides the following: it is fitted with a ...

  • Page 23

    Tb8100 installation guide connection 23 © tait electronics limited june 2005 taitnet this system interface board is fitted to reciters bearing the product code tba4xxx-0t1x. If purchased separately, it has the product code tba10t1. It is designed for use with mpt trunking systems. It provides the fo...

  • Page 24

    24 connection tb8100 installation guide © tait electronics limited june 2005 taitnet rs-232 this system interface board is fitted to reciters bearing the product code tba4xxx-0l0x or tba5xxx-0l0x. If purchased separately, it has the product code tba10l0. It is designed for use with mpt trunking syst...

  • Page 25: 2.4

    Tb8100 installation guide connection 25 © tait electronics limited june 2005 port switch) and modem or radio modem. Refer to tn-906 for more details on using an aps with tb8100 base stations. 2.4 service kit connections the tb8100 service kit is connected to the bss via the rs-232 serial port on the...

  • Page 26: 2.5

    26 connection tb8100 installation guide © tait electronics limited june 2005 2.5 rf connections important the pa may be damaged if the load is removed or switched while the pa is transmitting. To protect the pa output stage from load transients (i.E. Switching or removing the load), we recommend tha...

  • Page 27

    Tb8100 installation guide 27 © tait electronics limited june 2005 directive 1999/5/ec declaration of conformity da dansk undertegnede tait electronics limited erklærer herved, at følgende udstyr tbab1, tbac0 & tbah0 overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/ 5/ef. Se end...

  • Page 28: Tait Contact Information

    28 tb8100 installation guide © tait electronics limited june 2005 tait contact information tait radio communications corporate head office tait electronics ltd p.O. Box 1645 christchurch new zealand for the address and telephone number of regional offices, refer to the taitworld website: website: ht...