Valor accolade 806 Installer's And Owner's Manual - Page 3
of
10
INSTALLER’S AND OWNER’S GUIDE
Page 3
Figure 1. Appliance Dimensions
INSTALLATION
Location
This heater is intended for use in a fireplace opening generally conforming to British
Standard 1251 for a nominal 400mm (16 inch) or 450mm (18 inch) Fireplace. It may
also be located in other fireplace openings or in a wooden surround, where the following
dimensions are available.
Width
390 – 450mm
Height
555 – 590mm
Depth
At least 75mm
Alternatively the heater can be fitted to a flat wall or surround using the spacer frame
provided.
Installing
The heater must be fixed into position to prevent it from being tipped over.
The following fixing options are available: -
Screw fixing
Wire fixing
Spacer frame
The parts required for the above fixing options are included with this appliance.