MAINTAINING YOUR FIRE
Always disconnect the heater from the electricity supply by removing the 3 pin plug
and allowing the heater to cool before undertaking maintenance or replacing lamps.
Lamp Replacement
The lamp fitted to this heater is a long life type, but due to the indeterminate life span and
ease of replacement are specifically excluded from the guarantee.
To replace a lamp.
Remove the loose glass pebbles. Carefully remove the front surround by pulling the
surround off the strong magnets.
Slide the coloured lamp shroud off the lamp
Replace with an 18 –20 W E27 Edison screw “Philips Ecotone” Compact Fluorescent
Lamp. Do not fit any other type of lamp.
Replace the shroud.
Relocate the magnets as in figure 8, fit the surround and rearrange the glass pebbles.
Automatic Cut Out
A cut out is fitted to the heating element to prevent damage due to over heating. If it
operates due to an obstruction in the airflow, the heater must be turned off, unplugged
from the mains socket and allowed to cool for 15 minutes with the obstruction removed.
Care and Cleaning
The canopy trims and glass parts need only to be wiped clean with a dry soft cloth, do not
use polishes or abrasive materials.
Fault Finding
No light from the fuel effect: Possibly due to a lamp failure. Remove the lamp as
detailed above and check it in a table lamp that is known to work.
No heat or light: Check the wall socket by plugging in a known working appliance. If
functional check the 13A fuse in the heater plug.
Light but no heat: The automatic cut out may have operated, see above.
Disposal
At the end of the products serviceable life it should be disposed of thoughtfully and
safely in accordance with local authority regulations. The plug should be removed from
the mains cable. We suggest that you cut the mains cable from the heater to prevent any
future unsafe use of the appliance.