Veermount Technology TeleHawk 3 Installation Manual - page 14
Veermount Technology
Tele
Hawk
3
Installation manual
Page
13
of
14 pages
Statutory Information
The approved item consists of the TeleHawk3 panel assembly, which constitutes a hands free telephone call point to a
series of pre-programmed telephone numbers together with the associated Power and Termination Unit.
The TeleHawk3 apparatus is approved for connection to analogue speech circuit equipment approved under section
16(1) of the British Telecommunications Act (1981) and as designated by the Secretary of State under section 22(6) of
the Telecommunications Act of 1984.
The design meets the safety requirements of EN14003 and EN60950 with respect to TNV and as required by the
European Low Voltage Directive (LVD 73/23/EEC) when it is correctly installed and maintained. (See Declaration of
conformity on next page).
The apparatus has been approved for use of the following facilities;
1. Autocalling
2. Loudspeech
All other normal telephone facilities are provided as necessary from PSTN/PABX equipments.
The termination between the main panel and the PSTN master socket (NTP) is made via a standard BT603A (BS6312)
type plug and socket.
The apparatus MUST NOT be used with other series connected apparatus and if any other apparatus is connected in
parallel, due account must be taken of the REN loading.
The connection is a simple 2 wire (A-B) connection. There is no provision for a third, shunt, wire and as such the
apparatus must not be connected to main apparatus requiring a shunt wire.
The REN equivalent of an individual TeleHawk3 panel is 1. The maximum REN that is allowed on any PSTN circuit is
four. It is the responsibility of the Installer to ensure that if any equipments of other manufacture are connected in
parallel with the TeleHawk3, they do not cause this REN to be exceeded, and that they do not interfere with the
satisfactory operation of the TeleHawk3 panel.
Some of the above statements do not apply when the TeleHawk3 is used in conjunction with any approved PABX such
as the BT106.
See also Declaration of Conformity on the Last page :
Ref: Docs/Manuals/TeleHawk3
Issue 2.0 December 06