The connections to the external '
outside world
' should be made to the
inner
sides as indicated by the identification
labels set under the blocks and as shown above.
Right hand block:
TELE LINE
. (See detailed telephone line requirements in the next section).
Connect to pins 2 and 5 at the telephone master socket to the terminals marked LINE 1. Note that line polarity is
unimportant. (The second telephone line is not available in this model of TeleHawk3).
VID, 0v
.
If a video camera is fitted then the video signal is available between the terminals marked VID and 0v.
Left hand block:
Egress controls
EG2, EG1 & COM. By connecting a simple normally open push button between EG1 and COM, RL2 will
operate when the button is pressed, permitting exit from the zone it controls. Similarly, by connecting a simple
normally open push button between EG2 and COM, RL1 will operate, permitting exit from the second zone.
Door control
NO, RL1, NC
This provides a clean changeover relay contact for operating the door release solenoid or equivalent. If power is
required for lock release, then a separate power supply must be used or the internal +12V 1A supply may be
used if appropriate.
Note that the wiring shows the use of the PTU power for this. If the load is greater than 1A
total then an external supply must be used.
Gate control
NO, RL2, NC.
This provides a clean changeover relay contact for operating the gate release solenoid or equivalent. If power is
required for lock release, then a separate power supply must be used or the internal +12V 1A supply may be
used if appropriate.
Note that the wiring shows the use of the PTU power for this. If the load is greater than 1A
total then an external supply must be used.
SELV +12 Volt power.
This provides a fuse isolated power supply of 1Amp maximum load for use with external equipment. The
diagram shows the method of wiring this into the circuit.
240V AC MAINS CONNECTION
The 240V ac mains to drive the PSU is connected at the top left hand side of the box. It should be powered from an un-
switched spur with a fuse rating of 3A.
Ensure that the mains earth is correctly connected to the PTU at the mains
terminal block.
COMPLETION OF INSTALLATION
The inner control panel wiring should be checked and then the protective lid replaced and the four screws tightened
carefully.
Ensure that the earth is correctly connected to the front panel back box and the earth lead to the front panel is connected.
Ensure that the cable entry into the back box is protected against possible damage. Carefully dress the cables to allow
the front panel to sit correctly into the back box.
Insert the panel in the back box and secure the panel using the vandal resistant screws provided.
Ref: Docs/Manuals/TeleHawk3