Veermount Technology TeleHawk 3 Installation Manual - Installation and Wiring
Veermount Technology
Tele
Hawk
3
Installation manual
Page
3
of
14 pages
2.
Installation and wiring
The control panel is designed for setting into (Flush mount), or fixing onto (surface mount), a brick or stone type
structure. The Power and Termination Unit needs to be set inside the building and within 100 metres (cable run
distance) of the control panel.
The control panel should be sited so that the keyboard is easily accessible, at a suitable level for talking into the
Microphone (lower half) and listening through the Speaker (upper half). Also take into account the cabling to the
associated internal wall box unit. (See wiring details, Section 5, below).
For typical pedestrian use the height from finished ground level to the top of the back box should be no more than
1700mm.
This level may need to be reduced further where (for example) wheelchair access is provided.
Where the installation is designed for operation via a vehicle window, a compromise may be necessary according to the
range of sill heights likely to be encountered.
It is not necessary for users to speak directly into the microphone from close proximity; its sensitivity is such that
adequate output can be generated when the mouth to microphone distance is a metre or more. In practice, the limiting
factors are most likely to be the height at which the keyboard can be operated by a child or person in a wheelchair and
the background sound when in a noisy environment.
Tele
Hawk
3
CALL
CLR
0
9
8
7
6
5
4
3
2
1
TRADES
CONCIERGE
Key in
Flat No
and CALL
If error key CLR
Flush mounted TeleHawk3
DIMENSIONS (mm)
Height
Width
Depth
Flush Mounting – Standard version
360.0
205.0
60.0*
Surface Mounting –Standard version
323.5
154.5
80.0 max
Flush Mounting – PAC version
400.0
191.0
58.0*
Surface Mounting- PAC version 363.5 154.5
80.0
max
Control Box (if required)
331.0
359.0
84.0
* Flush mounting models require a cavity behind the panel as follows:
Standard version:
325 h x 175 w x 58 d
PAC version:
410 h x 1725 w x 58 d
Note that flush and surface models are secured in similar way in that the back box itself is directly screwed to the wall.
Ref: Docs/Manuals/TeleHawk3
Issue 2.0 December 06