CONTROL PANEL MOUNTING
The control panel should first be removed from its back box using the correct screw spinner for the security screws
(available from Veermount if required).
The back box requires four plugged holes to be set into the wall (surface mount version) or a cavity cut into the wall
(flush mount version) followed by the four plugged holes as for the surface version.
The mounting holes may most easily be drilled using the back box as a jig, taking care not to damage the box itself
whilst doing so.
Remember to make provision for the interlinking CAT5 cables between the control panel and the PTU
and also an earth
connection to the back box terminal.
The TeleHawk3 requires a maximum of 8 twisted pair cables to connect between the panel and the Power &
Termination Unit (PTU). The use of 2 off CAT5 type cables is strongly recommended for the purpose. (See below for
wiring details).
A suitable earth connection cable is also required.
The distance between the panel and the associated Power & Termination Unit should not exceed 50 metres.
POWER & TERMINATION UNIT.
The PTU wall box is provided with keyhole type slots to allow easy fitting to the wall.
Allow sufficient room around the box to remove the front cover and to easily cable into the unit from both the side
(mains) and either top or bottom control cabling. Knock out holes are provided in the box for this purpose.
TeleHawk3 itself is powered from the telephone line except for the display which is powered from the associated PTU.
The optional video camera is also powered from this source. Any lock release mechanism, barrier or gate operating
motor, etc. that is
switched
by the TeleHawk3 requires an external power source, although up to 1Amp and 12Volt DC
is available within the PTU for this purpose.
CONTROL PANEL CONNECTIONS
The connections are made along the bottom edge of the PCB in the control panel. Access is by removing the rear
protection box lid (four screws). The PCB will then be seen inside.
NO RL1 NC NO RL2 NC E2 E1 X1 X2 X3 COM
+12V
VID
PHONE LINES
TR 0v
1
2
TeleHawk control board
The terminations are via the screw terminal block at the base of the board. Slots and grommets are provided to allow the
cable(s) to pass safely through the protection box side.
Ref: Docs/Manuals/TeleHawk3