Vega VEGABAR 54 Product Information

Manual is about: pressure transmitter

Summary of VEGABAR 54

  • Page 1

    Level and pressure measure- ment hydrostatic vegabar 54 vegabar 64 vegabar 65 product information.

  • Page 2

    Contents 2 hydrostatic – level and pressure measurement contents 1 application, function, configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 type overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 3

    1 application, function, configuration area of application vegabar 54, 64 and 65 sensors are designed for front flush level and process measurement of gases, vapours and liquids. Application-optimised housings and materials ensure reliable use even in harsh environments. For extremely moist areas, ip ...

  • Page 4

    1 2 3 fig. 3: example of a vegabar 54 with connection g1 a and plastic housing in protection ip 66/ip 67 1 housing cover with integrated plicscom (optional) 2 housing with electronics 3 process fitting with measuring cell 1 2 3 4 5 fig. 4: example of a vegabar 54 with connection g1 a and aluminium ho...

  • Page 5

    Headbox fig. 8: pressure measurement on the headbox of a paper machine with vegabar 64 the pressure measurement in the headbox is used for speed control of the mixing pump. This must be a high precision meas- urement and reactionless. The optimum solution is vegabar 64 in completely front flush versi...

  • Page 6

    2 type overview vegabar 54 vegabar 64 vegabar 65 measuring cell: small certec ® certec ® metec ® diaphragm: ceramic ceramic metal products: gases, vapours and liquids, also with abrasive substances gases, vapours and liquids, also with abrasive substances gases, vapours and liquids also with higher ...

  • Page 7

    Indicating and adjustment module plicscom housing plastic stainless steel aluminium aluminium (double chamber) electronics 4 … 20 ma/hart profibus pa foundation fieldbus process fitting thread flange sanitary sensors certec ® - measuring cell metec ® - measuring cell approvals sil overfill protection g...

  • Page 8

    3 mounting information installation position vegabar functions in any installation position. Depending on the measuring system, the installation position can influence the measurement. This can be compensated by a position correc- tion. When installing plics ® instruments, choose a position you can e...

  • Page 9

    4 electrical connection 4.1 general requirements the supply voltage range can differ depending on the instrument version. The exact range is stated in the "technical data". Take note of country-specific installation standards (e.G. The vde regulations in germany) as well as prevailing safety regulatio...

  • Page 10

    Double chamber housing - two-wire i2c 1 1 2 fig. 13: connection hart two-wire, profibus pa, foundation fieldbus 1 power supply and signal output wire assignment, connection cable with version ip 66/ip 68, 1 bar + - 1 2 fig. 14: wire assignment, connection cable 1 br (+) and bl (-) for power supply or...

  • Page 11

    5 adjustment 5.1 overview vegabar can be adjusted with the following adjustment media: l the indicating and adjustment module plicscom l an adjustment software acc. To fdt/dtm standard, e.G. Pactware™ and pc and, depending on the signal output, also with: l a hart handheld (4 … 20 ma/hart) l the adj...

  • Page 12

    ~ = power supply vegaconnect 3 pactware / tm >pa 2 3 1 fig. 17: pc connected directly to the sensor 1 rs232 connection 2 vegabar 3 i²c adapter cable for vegaconnect 3 to adjust with pactware™, a vegaconnect 3 with i²c adapt- er cable (art. No. 2.27323) as well as a power supply unit is nec- essary i...

  • Page 13

    6 technical data general data common data 316l corresponds to 1.4404 or 1.4435 materials, non-wetted parts - housing plastic pbt (polyester), alu die-casting powder-coated, 316l - remote housing plastic pbt (polyester) - socket, wall mounting plate remote housing plastic pbt (polyester) - seal betwe...

  • Page 14

    Additional output variable, temperature (vegabar 54 and 64) processing is made via hart multidrop, profibus pa and foundation fieldbus range -50 … +150 °c (-58 … +302 °f) resolution 1 °c (1.8 °f) input variable parameter process pressure measuring ranges see product code recommended max. Turn down 1:...

  • Page 15

    Long-term stability long-term drift of the zero signal 4)5) vegabar 54 vegabar 64, 65 ambient conditions ambient, storage and transport temperature - without plicscom -40 … +80 °c (-40 … +176 °f) - with plicscom -20 … +70 °c (-4 … +158 °f) - ip 66/ip 68 and ip 68 version with pe connection cable -40...

  • Page 16

    Technical data 16 hydrostatic – level and pressure measurement or: l 1x closing cap ½ npt, 1x blind stopper ½ npt, plug m12x1 for ve- gadis 61 (optional) or: l 1x plug (depending on the version), 1x blind stopper m20x1.5; plug m12x1 for vegadis 61 (optional) spring-loaded terminals for wire cross se...

  • Page 17

    Technical data hydrostatic – level and pressure measurement 17 indicating and adjustment module power supply and data transmission through sensor via gold-plated sliding contacts (i²c bus) display lc display in full dot matrix adjustment elements 4 keys protection - unassembled ip 20 - mounted into ...

  • Page 18

    Technical data 18 hydrostatic – level and pressure measurement power supply - foundation fieldbus supply voltage - non-ex instrument 9 … 32 v dc - eex ia instrument 9 … 24 v dc supply voltage with lighted indicating and adjustment module 12) - non-ex instrument 12 … 32 v dc - eex ia instrument 12 … ...

  • Page 19

    Dimensions hydrostatic – level and pressure measurement 19 7 dimensions housing in protection ip 66/ip 67 112mm (4 13 / 32 ") 117mm (4 39 / 64 ") 116mm (4 9 / 16 ") 120mm (4 23 / 32 ") ~ 69mm (2 23 / 32 ") ø 77mm (3 1 / 32 ") ~ 69mm (2 23 / 32 ") ~ 116mm (4 9 / 16 ") ~ 87mm (3 27 / 64 ") ø 77mm (3 1...

  • Page 20

    Dimensions 20 hydrostatic – level and pressure measurement vegabar 54, fitting for paper industry pc pd pe 45,5mm (1 51 / 64 ") ø 26,3mm (1 1/32 ") 43,7mm (1 23 / 32 ") ø 34,6mm (1 23/64 ") ø 36mm (1 27/64 ") 43,7mm (1 23 / 32 ") ø 40,4mm (1 19/32 ") bf/bs vp ø 27,4mm (1 5/64 ") 29mm (1 9 / 64 ") 48m...

  • Page 21

    Dimensions hydrostatic – level and pressure measurement 21 vegabar 64, threaded and hygienic fitting - part 2 sw46 sw46 50mm (1 31 / 32 ") 50mm (1 31 / 32 ") 50mm (1 31 / 32 ") 60mm (2 23 / 64 ") 60mm (2 23 / 64 ") 51mm (2 1 / 64 ") ø 64mm (2 33/64 ") ø 78mm (3 5/64 ") ø 78mm (3 5/64 ") ø 92mm (3 5/8...

  • Page 22

    Dimensions 22 hydrostatic – level and pressure measurement vegabar 64, extension fitting for paper industry 158mm (6 7 / 32 ") 40mm (1 37 / 64 ") ø38mm (1 1 / 2 ") fg 43mm (1 11 / 16 ") 23mm ( 29 / 32 ") ø48mm (1 57 / 64 ") ev/ft 52mm (2 3 / 64 ") 24mm ( 15 / 16 ") ø48mm (1 57 / 64 ") ew ø59mm (2 21 ...

  • Page 23

    Dimensions hydrostatic – level and pressure measurement 23 vegabar 65, flange fitting 3 15 / 32 " 4 1 / 64 " 5 7 / 16 " 1 / 8 " 1 / 8 " 1 / 8 " 4xø 45 / 64 " 4xø 45 / 64 " 8xø 45 / 64 " 4 21 / 64 " 4 59 / 64 " 6 19 / 64 " 7 31 / 64 " 5 29 / 32 " 6 1 / 2 " 7 7 / 8 " 45 / 64 " 25 / 32 " 15 / 16 " fb 40 ...

  • Page 24

    Product code 24 hydrostatic – level and pressure measurement 8 product code vegabar 54 approval xx without xm ship approval cx atex ii 1g, 1/2g, 2g eex ia iic t6 ca atex ii 1g, 1/2g, 2g eex ia iic t6 + whg cm atex ii 1g, 1/2g, 2g eex ia iic t6 + ship approval dx atex ii 1/2g, 2g eex d ia iic t6 1) p...

  • Page 25

    Hydrostatic – level and pressure measurement 25 vegabar 65 approval xx without xm ship approval cx atex ii 1g, 1/2g, 2g eex ia iic t6 ca atex ii 1g, 1/2g, 2g eex ia iic t6 + whg cm atex ii 1g, 1/2g, 2g eex ia iic t6 + ship approval dx atex ii 1/2g, 2g eex d ia iic t6 1) process connection / material...

  • Page 26

    26 hydrostatic – level and pressure measurement 29235 -en -060411.

  • Page 27

    Hydrostatic – level and pressure measurement 27 29235 -en -060411.

  • Page 28

    Vega grieshaber kg am hohenstein 113 77761 schiltach germany phone +49 7836 50-0 fax +49 7836 50-201 e-mail: info@de.Vega.Com www.Vega.Com you can find at www.Vega.Com downloads of the following l operating instructions manuals l menu schematics l software l certificates l approvals and much, much mor...