Summary of VEGASWING 61

  • Page 1

    Operating instructions vibrating level switch for liquids vegaswing 61 - contactless electronic switch document id: 29223.

  • Page 2: Contents

    2 contents vegaswing 61 • - contactless electronic switch 29223-en-130409 contents 1 about this document 1.1 function ........................................................................................................................... 4 1.2 target group ..........................................

  • Page 3

    3 contents vegaswing 61 • - contactless electronic switch 29223-en-130409 supplementary documentation information: supplementary documents appropriate to the ordered version come withthedelivery.Youcanfindthemlistedinchapter"product descrip- tion". Instructions manuals for accessories and replacemen...

  • Page 4: 1  About This Document

    4 1 about this document vegaswing 61 • - contactless electronic switch 29223-en-130409 1 about this document 1.1 function this operating instructions manual provides all the information you need for mounting, connection and setup as well as important instruc- tionsformaintenanceandfaultrectification...

  • Page 5: 2  For Your Safety

    5 2 for your safety vegaswing 61 • - contactless electronic switch 29223-en-130409 2 for your safety 2.1 authorised personnel all operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and w...

  • Page 6

    6 2 for your safety vegaswing 61 • - contactless electronic switch 29223-en-130409 successfultesting.Youcanfindthececonformitydeclarationinthe downloadareaof"www.Vega.Com". 2.7 sil conformity vegaswing61fulfillstherequirementsoffunctionalsafetyaccord- ingtoiec61508resp.Iec61511.Youcanfindfurtherinfo...

  • Page 7: 3  Product Description

    7 3 product description vegaswing 61 • - contactless electronic switch 29223-en-130409 3 product description 3.1 configuration the scope of delivery encompasses: • vegaswing 61 point level switch • documentation – this operating instructions manual – safetymanual"functional safety (sil)"(optional) –...

  • Page 8

    8 3 product description vegaswing 61 • - contactless electronic switch 29223-en-130409 3.2 principle of operation vegaswing 61 is a point level sensor with tuning fork for level detection. It is designed for industrial use in all areas of process technology and can be used in liquids. Typicalapplica...

  • Page 9

    9 3 product description vegaswing 61 • - contactless electronic switch 29223-en-130409 • modeadjustmentforselectionoftheswitchingcondition(a/b) 3.4 storage and transport your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a ...

  • Page 10: 4 Mounting

    10 4 mounting vegaswing 61 • - contactless electronic switch 29223-en-130409 4 mounting 4.1 general instructions make sure that all parts of the instrument coming in direct contact with the process, especially the sensor element, process seal and process fittingandsuspensioncable,aresuitablefortheex...

  • Page 11

    11 4 mounting vegaswing 61 • - contactless electronic switch 29223-en-130409 1 fig. 3: mounting horizontal 1 switching point 1 2 fig. 4: horizontal installation (recommended mounting position, particularly for adhesive products) 1 switching point 2 markingwithscrewedversionontop,withflangeversionsdi...

  • Page 12

    12 4 mounting vegaswing 61 • - contactless electronic switch 29223-en-130409 fig. 6: measures against moisture penetration caution: do not hold vegaswing 61 on the tuning fork. Particularly with flangeortubeversions,thetuningforkcanbedamagedjustbythe weight of the instrument. Transport coated instru...

  • Page 13

    13 4 mounting vegaswing 61 • - contactless electronic switch 29223-en-130409 1 fig. 7: marking on the welded socket 1 marking incaseofhorizontalmountinginadhesiveandviscousproducts, the surfaces of the tuning fork should be vertical in order to reduce builduponthetuningfork.Onthescrewedversionyouwil...

  • Page 14

    14 5 connecting to power supply vegaswing 61 • - contactless electronic switch 29223-en-130409 5 connecting to power supply 5.1 preparing the connection always keep in mind the following safety instructions: • connect only in the complete absence of line voltage inhazardousareasyoumusttakenoteofther...

  • Page 15

    15 5 connecting to power supply vegaswing 61 • - contactless electronic switch 29223-en-130409 8. Check the hold of the wires in the terminals by lightly pulling on them 9. Tighten the compression nut of the cable entry. The seal ring must completely encircle the cable 10. Screw the housing cover ba...

  • Page 16

    16 5 connecting to power supply vegaswing 61 • - contactless electronic switch 29223-en-130409 information: the contactless electronic switch is always shown in non-operative condition. Warning: the instrument must not be operated without an intermediately connected load, because the electronics wou...

  • Page 17: 6 Setup

    17 6 setup vegaswing 61 • - contactless electronic switch 29223-en-130409 6 setup 6.1 general information thefiguresinbracketsrefertothefollowingillustrations. With plastic housings, the switching condition of the electronics can becheckedwhenthehousingcoverisclosed(controllamp).Withthe basicsetting...

  • Page 18

    18 6 setup vegaswing 61 • - contactless electronic switch 29223-en-130409 "function chart"(a-max.Detectionoroverflowprotection,b-min. Detectionordryrunprotection). Withthisdilswitch(3)youcansettheswitchingpointtoliquids havingadensitybetween0.5and0.7g/cm³(0.018and0.025lbs/ in³).Withthebasicsetting,l...

  • Page 19

    19 6 setup vegaswing 61 • - contactless electronic switch 29223-en-130409 level switching status control lamp failure any 2 1 switch open flashesred.

  • Page 20

    20 7maintenanceandfaultrectification vegaswing 61 • - contactless electronic switch 29223-en-130409 7 maintenanceandfaultrectification 7.1 maintenance if the instrument is used properly, no special maintenance is required in normal operation. 7.2 rectify faults the operator of the system is responsi...

  • Page 21

    21 7maintenanceandfaultrectification vegaswing 61 • - contactless electronic switch 29223-en-130409 error cause rectification vegaswing 61 signals "covered"withoutbeing submerged(overfillpro- tection) vegaswing 61 signals "uncovered"whenbeing submerged(dryrunpro- tection) operating voltage too low c...

  • Page 22

    22 7maintenanceandfaultrectification vegaswing 61 • - contactless electronic switch 29223-en-130409 youfindallinformationtotheelectronicsexchangeintheoperating instructions of the new electronics module. In general, all electronics modules of series sw60 can be inter- changed.Ifyouwanttouseanelectro...

  • Page 23: 8 Dismounting

    23 8 dismounting vegaswing 61 • - contactless electronic switch 29223-en-130409 8 dismounting 8.1 dismounting steps warning: before dismounting, be aware of dangerous process conditions such as e.G. Pressure in the vessel, high temperatures, corrosive or toxic products etc. Takenoteofchapters"mounti...

  • Page 24: 9 Supplement

    24 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 9 supplement 9.1 technical data general data material 316l corresponds to 1.4404 or 1.4435 materials, wetted parts Ʋ processfitting-thread 316l,hastelloyc22(2.4602) Ʋ processfitting-flange 316l, 316l with hastelloy c22 pl...

  • Page 25

    25 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 Ʋ standard r a 3µm(1.18 -4 in) Ʋ hygienicversion(3a) r a -5 in) Ʋ hygienicversion(3a) r a -5 in) processfittings Ʋ pipethread,cylindrical(din3852-a) g¾, g1 a Ʋ american pipe thread, conical (asmeb1.20.1) ¾ npt, 1 npt Ʋ fl...

  • Page 26

    26 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 influenceoftheprocesstemperatureontheswitchingpoint 1 3 4 2 10 ( 25 / 64 ") 8 ( 5 / 16 ") 6 ( 15 / 64 ") 4 ( 5 / 32 ") 2 ( 5 / 64 ") -2 ( -5 / 64 ") -4 ( -5 / 32 ") -6 ( -15 / 64 ") -8 ( -5 / 16 ") -10 ( -25 / 64 ") 0 0°c...

  • Page 27

    27 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 influenceoftheprocesspressuretotheswitchingpoint 1 2 3 4 12 (174,1) 38 (551,1) 25 (362,6) 51 (739,7) 64 (928,2) 10 ( 25 / 64 ") 8 ( 5 / 16 ") 6 ( 15 / 64 ") 4 ( 5 / 32 ") 2 ( 5 / 64 ") -2 ( -5 / 64 ") -4 ( -5 / 32 ") -6 (...

  • Page 28

    28 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 vegaswing 61 of 316l/hastelloy c4 (2.4610) -50…+150°c(-58…+302°f) processtemperature(threadorflange temperature)withtemperatureadapter (option) Ʋ vegaswing 61 of 316l/hastelloy c4 -50…+250°c(-58…+482°f) Ʋ vegaswing 61 wit...

  • Page 29

    29 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 1 2 -50 °c (-58 °f) 0°c (32 °f) 50°c (122 °f) 100°c (212 °f) 150°c (302 °f) 200°c (392 °f) 250°c (482 °f) 20 (290) -1 (-14,5) 40 (580) 64 (928) fig. 33: process temperature - process pressure with switch position 0.5 g/cm...

  • Page 30

    30 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 Ʋ max. 400ma(withi>300matheambienttemperaturecan bemax.60°c/140°f)max.4aupto40ms(notwhg specified) electrical protective measures protection rating ip 66/ip 67 overvoltage category iii protection class i approvals instrum...

  • Page 31

    31 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 vegaswing 61 g¾a, ¾"npt g1a, 1"npt 18,5 mm (0.73" ) 32 (g¾a, ¾"npt) 41 (g1a, 1"npt) 57 mm (2.24" ) 50 mm (1.97" ) ø 33,7 mm (1.33") 36 mm (1.42" ) 19 mm (0.75" ) 49 mm (1.93" ) 50 mm (1.97" ) 53 mm (2.09" ) 53 mm (2.09" )...

  • Page 32

    32 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 vegaswing 61, options 34 mm (1.34" ) 178 mm (7.01" ) 1 2 fig. 36: options 1 gas-tight leadthrough 2 temperature adapter.

  • Page 33

    33 9 supplement vegaswing 61 • - contactless electronic switch 29223-en-130409 9.3 industrial property rights vega product lines are global protected by industrial property rights. Further information see www.Vega.Com. Only in u.S.A.: further information see patent label at the sensor housing. Vega ...

  • Page 34

    34 notes vegaswing 61 • - contactless electronic switch 29223-en-130409.

  • Page 35

    35 notes vegaswing 61 • - contactless electronic switch 29223-en-130409.

  • Page 36

    Printing date: 29223-en-130409 all statements concerning scope of delivery, application, practical use and operat- ing conditions of the sensors and processing systems correspond to the information available at the time of printing. Subject to change without prior notice © vega grieshaber kg, schilt...