Verint nextiva s17xxe series User Manual - page 23
Verint Video Solutions
13
Nextiva Multiport S17XXe Series User Guide
Ensure that the right voltage is selected (check the 115V/230V red switch on the
back of the power supply).
For any other power supply, refer to the manufacturer documentation for the proper
wiring scheme.
4. Start SConfigurator.
The SConfigurator window appears.
5. In the General tab, click Program Options.
The Program Options window appears.
6. Check Detect All Units on LAN.
7. Ensure that the VSIP Port is 5510; otherwise, click Default.
8. Ensure that the Discovery IP Address is 255.255.255.255; otherwise, click Reset to
Broadcast.
9. Click OK.
10. Select the Units tab, then click Discover.
A device of type “Unknown” with a 169.254.X.Y IP address appears in the list; it
corresponds to your new device.