Wacker Neuson 0008954 Operator's manual - Maintenance
Maintenance
T01093en.fm
21
8.
Maintenance
8.1
Maintenance schedule
Task
Daily
before
operation
After the
first
20 hours
Monthly
or every
100 hours
Annually
or every
300 hours
Check air filter:
- Damage.
- Tightness.
- Filter element - clean or replace, if
necessary.
Check the tank seal for leaks - change, if
necessary.
Check fuel tank:
- Fuel level.
- Leaks.
- Lines for leaks.
- Check the tank seal for leaks - change, if
necessary.
Check engine oil level.
Change engine oil.
Check that gas control moves freely - oil gas
control or lubricate engine rods, if necessary.
Check and clean the spark plug.
Replace the spark plug.
Check V-belt - change if necessary.
Check exciter oil - fill if necessary.
Change exciter oil.
Check hydraulic oil - fill if necessary.
Relubricate guide handle head:
- Transport retainer.
- Spindle for guide handle height setting.
Check that the fastening screws are tight:
- Protective frame.
- Central suspension.
Exhaust silencer - remove combustion
residue from spark catcher filter.