Wacker Neuson 1030L3 Operator's Manual - Maintenance Work
T01127en.fm
59
Maintenance work
Internal filter (all models)
Wash out the dirty internal filter (3) in warm soap water using house-
hold dish washing detergent or filter cleaner.
Air cleaner cartridge (all models)
NOTICE:
The air cleaner cartridge (2) filters the intake air through fine paper fil-
ter lamella. Thus never wash out the cartridge or clean it with com-
pressed air.
Clean the air cleaner cartridge once a week.
Expand the lamella of the air cleaner cartridge slightly, lay it on a clean
pad and carefully tap against it.
Replace the air cleaner cartridge after every 100 hours of operation.
Replace it immediately if you notice a drop in power, a drop in engine
speed or smoke in the exhaust fumes.
Before assembling the filter system, check whether dirt particles have
fallen into the air intake port. If necessary, remove the dirt particles.