Wacker Neuson BTS 1030L3 Operator's Manual - Maintenance
Maintenance
T00963GB
55
NOTE: With the rope pulled all the way out, it must still be possible to
turn the pulley another 1/4 turn against the return spring.
ATTENCION! Injury hazard! When you pull out the starter rope
hold the starter handle firmly. It will whip back if the rope drum is
released by accident.
Assemble air duct in reverse order (see picture 63). Make sure that the
guide (25) is located inside the seat (26) at the fan housing.
When replaceing fan housing, it may be necessary to pull the starter
rope lightly so that the rope pulley catches.
8.9
Replace the return spring
Take off fan housing (see chapter “Starter rope replacement“).
Remove air duct from fan housing (see chapter “Starter rope
replacement“).
Remove retaining ring (1) (see accessories for extemal retaining ring
pliers).
Pull off rope drum (2).
Unscrew screws (3).
Carefully and evenly remove retum spring (4) from spring holder with
screw driver or similar tool. Be extremely careful, as return spring is
pretensed and could jump out of spring holder!
ATTENCION: Danger of bodily harm! Wear safety glasses and
safety gloves under all circumstances!
63