Wacker Neuson DPU 6055 Operator's Manual - page 26
of
44
T00796GB
24
OPERATION
Compaction without extension plates
If the vibration plates is used without extension plates, screw set of protective screws (8 pes) No. 0067519 into
the threaded boreholes situated in the lower mass, in order to avoid threads from being damaged.
Stopping the engine
☛
ATTENTION! Never switch off the engine with the automatic decompression (2) as this inevitably results
in damage to the valve drive and decompression mechanism.
1. Move the throttle control lever (8) to the stop.
2. Turn the ignition key to the stop position and then pull it out once the engine has stopped. The control lamp
will extinguish and the acoustic alarm will turn off.