Wacker Neuson EH 23 Low Vib Operator's Manual - page 42
Technical data
EH 23, 27
42
12.4
Extension cable
Only use permitted extension cables, see chapter Safety.
Refer to the following table for the required cross-section area of the exten-
sion cable:
Note:
Refer to the nameplate or the chapter Technical data (via the item
number) for the type designation and voltage rating of your machine.
WARNING
Electrical voltage.
Injuries from electrocution.
f Check power cable and extension cable for signs of damage.
f Only use extension cables for which grounded conductors are connected to
the plug and the coupling (only for machines of class rating I, see chapter
Technical Data).
Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
100 1~
< 17
1.5
< 29
2.5
< 46
4
< 68
6
115 1~
< 23
2.5
< 36
4
230 1~
< 56
1.5
< 92
2.5
< 147
4
120 1~
< 20
1.5
< 34
2.5
< 55
4.0
127 1~
< 24
1.5
< 40
2.5
< 64
4.0