Waldorf GP8121GE Installation And Operation Manual - page 12
10
Installation
Electrical Connection
NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY A QUALIFIED
PERSON.
Each appliance should be connected to an adequately protected power supply and isolation switch
mounted adjacent to, but not behind appliance. This switch must be clearly marked and readily accessible
in case of fire.
1.
Check electricity supply is correct as shown on Rat-
ing Plate attached to lower front hand side of front
sill panel.
2.
Supply terminal connections are located at rear of
appliance. Refer to ‘Electrical Connections’ in
‘Dimensions’ section of manual.
3.
Open oven door and remove oven control panel to
allow connection access for electrical supply.
4.
Connect mains supply to L1, L2 and L3 connection
terminals. Refer to 'Electrical Supply Requirements'
section for connection details.
NOTE: This appliance can be converted from 3 Phase
to Single Phase supply by connecting single
phase input to L1 and adding a bridge wire
between L1, L2 and L3 connections, (refer to
Fig 3 opposite and information shown in
'Electrical Supply Requirements Table' in
'Specifications' Section).
5.
Connect neutral and earth conductors to neutral stud
and earth stud respectively.
6.
For all connections ensure that conductors are secure
and appropriately terminated.
7.
Tighten cable gland to secure against tension on cable.
8.
Check that the polarity of each connection is correct to the mains connection terminals markings on
the appliance.
NOTE:
This appliance must be earthed.
Fixed wiring installations must incorporate an all-pole disconnection switch.
9.
Correctly locate appliance into its final operating position and using a spirit level, adjust legs so that
appliance is level and at correct height.
10. Connect power supply to appliance.
11. Check electrical supply is within input rating specification, refer to ‘Specifications’ section).
Add bridging
wires between
L1, L2 and L3.
Neutral supply
connection to N
Phase supply
connection to L1
P
N
Fig 4
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
Warning
Changing supply from 3 phase to single phase will increase electrical current
loading on supply cable. Ensure supply cable used is of a sufficient size for
current loading, refer to 'Electrical Supply Requirements' table overleaf.