Waldorf GP8121GE Installation And Operation Manual - page 27
25
Gas Conversion and Specifications
Gas Specifications
- Non CE Only (Australia / New Zealand):
- CE Only:
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
1.
Note 1 Gas Control Valve is fitted with a maximum flow bypass blanking screw, non adjustable.
Note 2 Burner operating pressure is to be measured at griddle gas control valve outlet test point
with one griddle burner operating at full setting. Operating pressure is ex-factory set,
through appliance regulator and is not to be adjusted, apart from when carrying out gas
conversion, if required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas (G20)
Propane (G31)
GP8910GE/GEC
GP8121GE/GEC
GP8910GE/GEC
GP8121GE/GEC
Main Burner Injector
3.00mm
2.85mm
1.80mm
1.70mm
Pilot Burner Injector
0.41
0.25
Low Fire Adjustment
1 Full Turn Counter Clockwise from the 'Fully In' Position
High Fire Adjustment
Maximum Flow Screw. Fully In c.w. (Note 1)
Operating Pressure
8.2 mbar (Note 2)
26 mbar (Note 2)
Supply Pressure
20 mbar
37 mbar
Gas Regulator Cap Screw
Natural Gas
LP Gas (Propane)
GP8910GE/GEC
GP8121GE/GEC
GP8910GE/GEC
GP8121GE/GEC
Griddle
Main Burner
3.00mm
2.85mm
1.80mm
1.70mm
Pilot Burner
0.41
0.25
Low Fire Adjustment
1 full turn counter clockwise from the Fully ‘IN’ position
High Fire Adjustment
Maximum Flow Screw. Fully ‘IN’ (
Note 1
)
Operating Pressure
0.90 kPa (Note 2)
2.6 kPa (Note 2)
Gas Regulator Cap Screw