WANDERS STEALTH - SCHEMATICS Instructions For Use Intallation Manual - Installation Possibilities
4
Installation possibilities
The Stealth can be installed in many different ways. The two main possibilities are:
1.
Through the wall
2.
Through the roof
The stove may only be installed using flue material approved by Wanders!
For installation through the wall or through the roof, the under mentioned
conditions need to be respected:
1.
For installation immediately against the façade, at least 1 meter of flue
pipe should be placed vertically. Then the elbow and then the wall-outlet.
2.
For installation farther away from the façade, first place 1 meter of flue
pipe
The length of pipes used horizontally should never be over 3 meters, excl.
3.
The maximum total length is 10 meters ( elbows count for 2 meter !)
Explanation of the installation possibilities
For a right angle count 2 meters and for a 45 degrees bend count 0,5 meter. If
installed through the façade or through the roof, the length of the wall- or roof
outlet does not have to be included in the calculation. The maximum total length is
the sum of the length of the flue pipes, plus the calculated length of the bends. In
figure 1 this is illustrated by means of 4 examples. Here the maximum flue pipe
length is mentioned for installation through the roof. For a through the wall
installation the maximum horizontal length is drawn. The vertical length should be
4 meter at the most as 4+4+(1x2)=10
The wall outlet is supplied with the following parts:
*wall outlet 500 mm.
* fitting ring
The roof outlet set, flue pipes and bends are packed individually and supplied with
fitting ring. Additionally a tile and plate are available for an outlet via a flat or slope
roof.