WeatherTRAK ET Pro3 Installation Instructions
©2013HydroPointDataSystems,Inc.Allrightsreserved.WTETP3II0513
5
800.362.8774 • hydropoint.com
1 2 3 4 5 6 7 8 9 10 11 12 MV1 VC
13 14 15 16 17 18 19 20 21 22 23 24
VC
FL1
25 26 27 28 29 30 31 32 33 34 35 36 MV1 VC
37 38 39 40 41 42 43 44 45 46 47 48
VC
FL2
!
@
#
$
%
^
&
*
Figure 2
Station Output Board Design
Note:Stationoutputboards12-24and25-48areidentical,but
donotsupporttworainsensors.Terminatetheflowsensor
andrainsensorwiresinthe12-24stationoutputboardonly.
Interchangeable Transformer
TheWeatherTRAKETPro3shipswiththetransformerontheright
sideoftheenclosure.Thisenclosuredesignallowsthetransformer
tobemovedtotheleftsidetoaccommodateelectricalconnections
asneeded.Themountingbracketisinterchangeabletosimplify
relocatingthetransformertotheleftsidewhennecessary.
Figure 3
Interchangeable Transformer and Ground Lug
Note:Ifthetransformerisre-locatedtotheleftside,thenrelo-
catethegroundlugtotherightsideasshowninFigure3.
Center Drill Points for Rain Sensor Mounting
Thebottomleftandrightoutersidesoftheenclosurehavetwo
setsofdrillingcenterpoints.Thesedrillingpointsareforenclosure
mountingforspecificIrritrolorTorowirelessorwiredrainorrain/
freezesensors.Two(2-qty)self-tappingstainlesssteelscrewsare
tapedtotheinsideoftheenclosuretomountarainsensorreceiver
whenneeded.
Figure 4
Drill Points for Rain Switch Mounting
Note:Mounttherainsensorreceiverontheoppositesideof
thetransformerlocationtoavoidreceptionissuesforwireless
models.
Removable Command Module
Thefaceplateorcommandmodulecanbeeasilyremovedorslid
downintoalowerpositionbylooseningthecaptivescrewsbyhand.
Removingthecommandmoduleprovidesaccesstotherainswitch
inputand24-VACsource.
Note:Ifpanelremovalisnecessary,supportitwithonehand,
thendisconnectthecableswiththeotherhandandsetit
asidecarefully.
Figure 5
Removable Command Module