2) Network menu
-
Refresh: If selecting it, all local cameras are listed up. If using this menu, it is needless to enter
each local camera’s IP address manually in “Login” menu.
D. Normal Recording
* There are four types (Weekday Day/Weekday Night/Weekend Day/Weekend Night).
- Normal
Recording:
There are five conditions
(No Rec./Low/Standard/High/Custom). All conditions except “Custom” operate together with
“Frame Rate” and “Quality” automatically; 3fps/Q1 in “Low”, 10fps/Q3 in “Standard”, and
20fps/Q5 in “High”. When setting “Custom”, Frame Rate and Quality can be set separately.
- Special
Time
Recording:
There are five conditions
(No Rec./Low/Standard/High/Schedule). It can be set in ‘System’ menu.
-
Alarm Recording: Set “On/Off” with using ◄◄ button or ►► button after pressing [Enter] key.
E. Alarm Recording
* Among these menus, some menu may not be activated. Namely, setting menus are different according to
camera type(analogue camera/network camera). In addition to that, WebEye series doesn’t support
“Alarm Recording” currently. WebEye can support this menu after upgrading Firmware in July.
- IP Cam Event: It is only for I-Rec series(Ch.5 ~ Ch.16) currently. If setting as “On” after
registering I-Rec series, its related data are recorded according to setting menu in camera’s
admin menu.
-
MD/S1/S2/S3/S4: It is only for analogue cameras(Ch.1 ~ Ch.4). Be carious that DVR is set on
the base of NO(Normal Open) type sensor.
- Alarm
Recording:
There are five conditions.
(No Rec./Low/Standard/High/Custom) All conditions except “Custom” operate together with
“Frame Rate” and “Quality” automatically. When setting “Custom”, Frame Rate and Quality
can be set separately.
-
Pre/Post Alarm: Maximal 10 seconds can be set.