WEG SSW-08 User Manual - page 14
3
Installation and Connection
SSW-08 | 9
Table 3.1: Installation data with dimensions in mm (in)
SSW-08
Model
Height
H
mm
(in)
Width
L
mm
(in)
Depth
P
mm
(in)
A
mm
(in)
B
mm
(in)
C
mm
(in)
D
mm
(in)
Mountin
Screw
Weight
kg
(lb)
Degree
of
Protection
17 A
24 A
30 A
162
(6.38)
95
(3.74)
157
(6.18)
85
(3.35)
120
(4.72)
5
(0.20)
4
(0.16)
M4
1.3
(2.9)
IP20
45 A
61 A
85 A
208
(8.19)
144
(5.67)
203
(7.99)
132
(5.2)
148
(5.83)
6
(0.24)
3.4
(0.13)
M4
3.3
(7.28)
IP20
130 A
171 A
200 A
276
(10.9)
223
(8.78)
220
(8.66)
208
(8.19)
210
(8.27)
7.5
(0.3)
5
(0.2)
M5
7.6
(16.8)
IP00 *
255 A
312 A
365 A
412 A
331
(13.0)
227
(8.94)
242
(9.53)
200
(7.87)
280
(11.0)
15
(0.59)
9
(0.35)
M8
9.2
(20.32)
IP00 *
* IP20 with optional.
3.1.3 Mounting Specifications
To install the Soft-Starter SSW-08 leave at least the free spaces surrounding the Soft-Starter
as in figure 3.2 below. The dimensions of these free spaces are described in table 3.2.
Table 3.2: Recommended free spaces
SSW-08
Model
A
mm
(in)
B
mm
(in)
C
mm
(in)
17 A
24 A
30 A
50
(2)
50
(2)
30
(1.2)
45 A
61 A
85 A
80
(3.2)
80
(3.2)
30
(1.2)
130 A
171 A
200 A
100
(4)
100
(4)
30
(1.2)
255 A
312 A
365 A
412 A
150
(6)
150
(6)
30
(1.2)
Install the Soft-Starter SSW-08 in the vertical position according to the following recommendations:
1) Install on a reasonably flat surface;
2) Do not put heat sensitive components immediately above the Soft-Starter SSW-08.
ATTENTION!
If a Soft-Starter SSW-08 is installed on top of another use the minimum distance
A + B and diverge from the top Soft-Starter the hot air that comes from the one beneath it.
ATTENTION!
Independent conduits or cable trays must be planned for physic separation of signal,
control and power cables. (Refer to item 3.2 Electric Installation).