OVEN GAS SPECIFICATIONS
GAS CODE LIMITATIONS
The installation of this appliance must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223 1 or the Natural Gas Installation Code CAN/CGA-B149 1, as applicable including:
1.
The appliance and its individual shutoff valve (supplied by others) must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psi (3 45 kPa)
2.
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve (supplied by
others) during any pressure testing of the gas supply piping system at test pressure, equal to or less than 1/2 psi (3 45 kPa)
The incoming gas supply pressure must not exceed 1/2 psi (14 inches W C ) If the incoming gas pressure exceeds 1/2 psi, an
external gas regulator must be installed in the supply line If the supply pressure is less than 1/2 psi, no external regulator is
required
The installer should bleed any air out of the gas line supplying the oven All gas connections and fittings on the oven should be leak
checked with an approved soap solution
CHECKING THE BURNER MANIFOLD PRESSURE
The burner manifold pressure has been set at the factory However it should be checked by the installer The pressure should be
checked at the outlet tap on the Honeywell gas valve, located on the back of the control box Once the manometer is connected,
turn the oven on and use the knob on the oven to adjust the flame to its maximum height Then check the manifold pressure
FACTORY SPECIFIED MANIFOLD PRESSURE
Radiant Flame Burner(s)
Natural Gas (NG): 5" W C
Propane (LP): 9 5" W C
TOTAL BTU/HR RATING
See data plate for your specific model.
This information can also be found on the data plate located beneath the oven
GAS SPECIFICATIONS