9. Maintenance
Cleaning the Corotrons
The Corotrons should be cleaned every day and
after 5,000 prints.
1.
Open the Front Doors and slowly pull out the
cleaning wand for each corotron fully and
then push the wand back into place.
After the corotrons are cleaned, follow the
prompts on the UI to record the activity.
If it is not seated properly, the User Interface will
display the information on the screen. Re-seat the
appropriate corotron.
CAUTION:
If any problems occur while cleaning
the pad or re-seating the wand, and/or if the above
screen is continually displayed, call your Xerox
service representative for assistance.
2.
Once all the Corotron Cleaning Wands are
properly seated in the corotron assembly, the
User Interface displays the Interlock Open
screen. Close the Front Doors.