Xpr EX9 Manual - page 2
EX9 Wireless Radio Keypad User Manual v1.3
2
EX9-43B
TX2A
RX2
Contents
1
Product Description ..................................................................................................................... 2
2
Technical Specifications .............................................................................................................. 2
3
Mounting ..................................................................................................................................... 3
4
Terminal blocks and Jumper settings ........................................................................................... 3
5
Programming ............................................................................................................................... 4
6
Programming Flowchart ............................................................................................................... 6
7
Relay Settings ............................................................................................................................. 7
8
Total Reset ................................................................................................................................. 8
9
Operating the wireless keypad .................................................................................................... 8
10 Examples
.................................................................................................................................... 8
1) PRODUCT DESCRIPTION
EX9 is a set of wireless rolling
code keypad (EX9-43B) as a
transmitter and radio receiver
RX2. Only enrolled code in the
transmitter and memorized in the
receiver will activate the relay
output. The receiver can also
memorize code from the remote
transmitter TX2A.
Programming/deleting of the codes, the transmission duration is done at the keypad, memorizing the
codes and programming of the relays (time, mode) is done at the radio receiver.
2) TECHNICAL SPECIFICATIONS
EX9-43B
Keys
Backlit polycarbonate
Channels
10
Programming
Master Code
1
Users codes
99
Relays time setup
1 to 10 seconds
Range
120 mt in open space
Green led
Key press/ error and confirmation signal/
transmission in progress
Red led
Keypad locked indicator
Amber led
Configuration menu entrance
Buzzer
1
Power supply
12/24V AC/DC input and/or 9V battery
Max absorption
27mA in transmission with 9V battery
120mA in transmission with 24Vac power
supply
IP rating
65
Dimensions (mm)
119,5x83,5x40
RX2
Codifying
Rolling code
Memorisable
transmitters
- 1000 with memory - 30 without
memory
Power supply
12 Vac/dc Jumper C closed 24 Vac/dc
Jumper C open
Consumption
50mA
Channels
2
Antenna
Tuned at 433.92 MHz
Frequency
433.92 MHz
Reach
80 - 250 mt
Relay contact
1A up to 30 Vdc / 0.5A up to 42.4
Vac
Temperature