Yamaha F50D Servise Manual - page 110
Electrical system
5-21
ELEC
TIP:
9
To prevent the engine from starting when
cranking it, make sure to disconnect all
spark plug caps.
9
Measure the input voltage while the engine
is cranking.
4.
Turn the engine start switch to “OFF”,
and then disconnect the special service
tool
1
.
5.
Connect the special service tool
1
to the
hour meter coupler
b
.
6.
Connect the battery leads to the connec-
tor
c
and
d
, and then check that the all
segments are displayed on hour meter
for 2 seconds. Replace the hour meter if
there is no display.
7.
Disconnect the battery leads and special
service tool
1
, and then connect the
hour meter coupler
a
.
Starting unit and components
Checking the fuse
1.
Check the fuse
1
and fuse holder
2
for
continuity. Replace if there is no continu-
ity.
Checking the starter relay
1.
Disconnect the starter relay lead connec-
tor
a
.
2.
Set the gear shift to the “N” position.
3.
Turn the engine start switch to “START”,
and then measure the input voltage at
the starter relay lead connector
a
.
Check the engine start switch, neutral
switch and wiring harness if below speci-
fication.
4.
Disconnect the ground lead
b
, starter
motor lead
1
and positive battery lead
2
, and then remove the starter relay
3
.
Y
G
B
O
P
Y
B
G/W
R
b
1
c
d
a
b
G/W
B
Y
Starter relay input voltage:
Brown
a
–Ground
12.0 V (battery voltage)
1
2
Br
Br
B
a
a