4RF Aprisa XE User Manual - page 160
Protected terminals | 159
Mounting the MHSB radios and switch
Once the IP addresses are correctly configured, it is important to connect the A and B radios' Ethernet
and Alarm ports correctly. In general, mount radio A above the MHSB switch and radio B below the
MHSB switch:
There is an Ethernet connection between any of the four Ethernet ports on each radio and the
Ethernet port on the Tributary switch. There is also a connection between radio A and radio B, which
ensures Ethernet traffic is maintained if a radio loses power.
The Ethernet port on the protection switch can be connected to an Ethernet hub or switch to allow
multiple connections.
Important: The management Ethernet capacity on each of the four radios in the protected terminal
must be identical for remote communications to work and there should only be one IP connection to
the management network (via the tributary switch Ethernet port).