Specifications | 251
External alarm interfaces
Alarm inputs
Detector type
Isolated current detectors
Detection current
5.0 to 6.5 mA (constant current)
Detection voltage
9 to 60 VDC or AC rms
Alarm outputs Contact type
Isolated semiconductor relay type contacts
Maximum current
100 mA
Maximum voltage
0 to 60 VDC or AC rms
Ouput impedance
45 Ω closed
> 100 kΩ open
Overall
Latency
The latency for an alarm presented on an external alarm input
to the alarm being output on an external alarm output is < 2
seconds
Auxiliary interfaces
Management
Configuration and
management
Embedded web server and / or SNMP accessed via Ethernet
interface or across link
Test points
RSSI
Front panel test point for measuring the RSSI voltage