5Star Systems Spica 250M User Manual - page 19
5Star Systems – Spica 250M – User manual
Tel: 0031 23 55 44 611
19
Lamp On automatically
This function enables to switch On the lamp automatically after switching On the
fixture. Use the [Up] and [Down] keys to select `On` if you wish to switch On the
lamp automatically after switching On the fixture or ´Off`` if you wish the lamp off
after switching On the fixture and press [Enter] to confirm or [Mode] to cancel
and return to the menu.
DMX values
Readout DMX values of each channel received by the fixture. Use the [Up] and
[Down] keys to select desired channel and press [Enter] to read its value
coming to the fixture or [Mode] to cancel and return to the menu.
Automatic blackout of Display
This function allows you to keep the display On or to turn Off automatically 2
min. after last pressing any key on the control board. Use the [Up] and [Down]
keys to select "On" if you wish to keep the display “On” or "Off" if you wish to
turn Off automatically 2 minutes after last pressing any key on the control board
and press [Enter] to confirm or [Mode] to cancel and return to the menu.
Display intensity
By this function you can adjust from 20 to 100 the intensity of the display. Use
the [Up] and [Down] keys to select the level of the display intensity and press
[Enter] to confirm or [Mode] to cancel and return to the menu.
Lamp Off via DMX
This function allows you to switch Off the lamp by DMX. Use the [Up] and
[Down] keys to select "On" if you want to switch Off the lamp by DMX or "Off" if
you don’t want to switch Off the lamp by DMX and press [Enter] to confirm or
[Mode] to cancel and return to the menu.
Temperature
Temperature readouts of fixture inside in Celsius. Inside temperatures below
70° C are not critical. 70° C and more lead to the lamp being switched off.
Please note that the outside temperature should not exceed 45° C.
Low fan speed operating
By using this function you can choose 4 types of low fan speed operating.
Browse through this menu by the pressing [Up] and [Down] keys - the display
shows step by step these messages: "HIGH, reG, LoOF, LoHI". Press [Enter]
if you wish to select one of them or [Mode] to cancel and return to the menu.
High (max.) speed of fans
The cooling fans work on max. speed (max. cooling)
Continuous controlling of the fan speed
The fan keeps the adjusted low speed until the temperature exceeds max.
inside temp., then the SPICA 250M automatically switches Off the lamp.