Low/high speed of the fan operating
the fan keeps the adjusted low speed until the temperature exceeds max.
inside temp of the fixture, then the SPICA 250M automatically switch from low
to high the fan speed.
Default settings
Press [Enter] to reset all fixture personalities (not the adjusting functions) to the
default values. On the display will appear “rst” meaning that the fixture makes
the reset. See the table of personality setting and their positions.
Adjusting the default positions of colour, gobo and effect wheels
By this function you can calibrate and adjust the colour, gobo and effect wheels
to their standard/right positions. Use the [Up] and [Down] keys to browse
through the adjusting menu - the display shows step by step these messages:
"PAn, Tilt, SPEd, Colo, EFEC, Prot, rGOB, Grot, Foc, Stro, dimr, FCAL" by
which you can adjust the fixture to the required/desired position (0-255) before
the function calibration. Then when the positioning is finished use the last
"FCAL" function (Fixture calibration).
1. Calibration via the control board
Press [Enter] and the [Up] and [Down] keys in order to display the following messages: "Colo,
EFEC, rGob, Grot" for very smooth function calibration. Select one of them, press [Enter] and