ABB RED615 Product Manual

Manual is about: 615 series

Summary of RED615

  • Page 1

    Line differential protection and control red615 product guide.

  • Page 2

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a contents disclaimer the information in this document is subject to change without notice and should not be construed as a commitment by abb oy. Abb oy assumes no responsibility for any errors that may appear in thi...

  • Page 3

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a issued: october 008 revision: a / 0 october 008 1. Description red615, member of abb’s 615 product series, is a phase-segregated two-end line differential protection and control ied (intel- ligent electronic device...

  • Page 4

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a continued measurement transient disturbance recorder • three-phase current measurement • current sequence components • differential current measurement • bias current measurement • • = included 3. Protectionfunctio...

  • Page 5

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a 4. Application red615 can be used in a variety of applica- tions requiring an absolutely selective unit type protection system. The zone-of-protec- tion of a line differential protection system is the feeder sectio...

  • Page 6

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a fig. 3 red615 protecting an interconnecting feeder between two primary distribution substations under certain operational circumstances, such as maintenance of primary equipment or substation extension projects the...

  • Page 7

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a 5. Control the ied offers control of one circuit breaker with dedicated push-buttons for opening and closing. Interlocking schemes required by the application are configured with the signal matrix tool in pcm600. 6...

  • Page 8

    Abb 8 line differential protection and control red615 product version: 1.1 1mrs756500 a the fault recording can be triggered by the start signal or the trip signal of a protection block, or by both. The available measurement modes include dft, rms and peak-to-peak. In addition, the maximum demand cu...

  • Page 9

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a cation, persists. The two high-set stages of the overcurrent protection are further by default released. 13.Accesscontrol to protect the ied from unauthorized access and to maintain information integrity, the ied i...

  • Page 10

    Abb 10 line differential protection and control red615 product version: 1.1 1mrs756500 a supported communication interfaces and protocols 100base-tx rj-45 rs-485 +irig-b fibre-optic st iec 61850-8-1 • - - modbus rtu/ascii - • • modbus tcp - • - - • = supported bance files and storing of the latest f...

  • Page 11

    Abb 11 line differential protection and control red615 product version: 1.1 1mrs756500 a power supply description value u aux nominal 100, 110, 120, 220, 240 v ac, 50 and 60 hz 48, 60, 110, 125, 220, 250 v dc u aux variation 38...110% of u n (38...264 v ac) 80...120% of u n (38.4...300 v dc) burden ...

  • Page 12

    Abb 1 line differential protection and control red615 product version: 1.1 1mrs756500 a energizing inputs rated frequency 50/60 hz ± 5 hz current inputs rated current, i n 1/5 a 1) thermal withstand capability: • continuously • for 1 s for 1 s • for 10 s 20 a 500 a 100 a dynamic current withstand: •...

  • Page 13

    Abb 1 line differential protection and control red615 product version: 1.1 1mrs756500 a irf relay change over - type signal output relay rated voltage 250 v ac/dc continuous contact carry 5 a make and carry for 3.0 s 10 a make and carry 0.5 s 15 a breaking capacity when the control-circuit time cons...

  • Page 14

    Abb 1 line differential protection and control red615 product version: 1.1 1mrs756500 a degree of protection of flush-mounted ied front side ip 54 rear side, connection terminals ip 20 environmental conditions and tests environmental conditions operating temperature range -25...+55ºc (continuous) sh...

  • Page 15

    Abb 1 line differential protection and control red615 product version: 1.1 1mrs756500 a radio frequency interference tests: • conducted, common mode • radiated, amplitude-modulated • radiated, pulse-modulated according to iec 61000-4-6 and iec 60255-22-6, level 3 10 v (emf), f = 150 khz...80 mhz acc...

  • Page 16

    Abb 1 line differential protection and control red615 product version: 1.1 1mrs756500 a insulation and mechanical tests insulation tests dielectric tests: according to iec 60255-5 • test voltage 2 kv, 50 hz, 1 min 500 v, 50 hz, 1min, communication impulse voltage test: according to iec 60255-5 • tes...

  • Page 17

    Abb 1 line differential protection and control red615 product version: 1.1 1mrs756500 a protection communication link, fibre-optic wavelength fibre type 2) connector permitted path attenuation 1) distance 1300 nm mm 62.5/125 μm lc ≤ 2 km 1300 nm sm 9/125 μm lc 2 - 20 km 1) maximum allowed attenuatio...

  • Page 18

    Abb 18 line differential protection and control red615 product version: 1.1 1mrs756500 a binary signal transfer (bstggio) signalling delay 1) with the symmetrical communication channel (as when using dedicated fibre optic) 2) without additional delay in the communication channel (as when using dedic...

  • Page 19

    Abb 1 line differential protection and control red615 product version: 1.1 1mrs756500 a 1) set operate delay time = 0,02 s, operate curve type = iec definite time, measurement mode = default (depends on stage), current before fault = 0.0 x in, fn = 50 hz, fault current in one phase with nominal freq...

  • Page 20

    Abb 0 line differential protection and control red615 product version: 1.1 1mrs756500 a negative phase-sequence current protection (nsptoc) operation accuracy depending on the frequency of the current measured: f n = ±2hz ±1.5% of the set value or ±0.002 x i n start time 1) 2) minimum typical maximu...

  • Page 21

    Abb 1 line differential protection and control red615 product version: 1.1 1mrs756500 a circuit breaker failure protection (ccbrbrf) main settings parameter function value (range) step current value (operating phase current) ccbrbrf 0.05...1.00 x i n 0.05 current value res (operating residual curren...

  • Page 22

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a operating characteristics parameter values (range) operating curve type 1=ansi ext. Inv. 2=ansi very. Inv. 3=ansi norm. Inv. 4=ansi mod inv. 5=ansi def. Time 6=l.T.E. Inv. 7=l.T.V. Inv. 8=l.T. Inv. 9=iec norm. Inv....

  • Page 23

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a 18.Displayoptions the ied is available with two optional dis- plays, a large one and a small one. Both lcd displays offer full front-panel user-interface functionality with menu navigation and menu views. The large...

  • Page 24

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a 19.Mountingmethods by means of appropriate mounting acces- sories the standard ied case for the 615 series ieds can be flush mounted, semi-flush mounted or wall mounted. The flush mount- ed and wall mounted ied cas...

  • Page 25

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a 21.Selectionand orderingdata the ied type and serial number label identi- fies the ied. The label is placed above the hmi on the upper part of the plug-in-unit. An order number label is placed on the side of the pl...

  • Page 26

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a h b d a a c a d a b b 1 a n n 1 x a # description 9 substation communication (serial) 1) 2) rs485 (connector incl. Irig-b) a st glass fi bre (rx/tx) b none n 10 protection and substation communication (ethernet) 1)...

  • Page 27

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a h b d a a c a d a b b 1 a n n 1 x a # description 12 language english 1 13 front panel small lcd a large lcd b 14 option 1 none n 15 option 2 none n 16 power supply 48...250 v dc, 100...240 v ac 1 17 vacant digit v...

  • Page 28

    Abb 8 line differential protection and control red615 product version: 1.1 1mrs756500 a 22.Accessoriesand orderingdata mounting accessories item order nr semi-flush mounting kit 1mrs050696 wall mounting kit 1mrs050697 inclined semi-flush mounting kit 1mrs050831 19 ” rack mounting kit with cutout for...

  • Page 29

    Abb line differential protection and control red615 product version: 1.1 1mrs756500 a tool function overview function webhmi pcm600 ied signal configuration (signal matrix tool) - • iec 61850 communication configuration, goose (communication configuration tool) - • modbus ® communication configurati...

  • Page 30

    Abb 0 line differential protection and control red615 product version: 1.1 1mrs756500 a 24.Terminaldiagram fig. 10 terminal diagram of standard configuration a.

  • Page 31

    Abb 1 line differential protection and control red615 product version: 1.1 1mrs756500 a 25.Functions,codes andsymbols red615 functions, codes and symbols functions iec 61850 iec 60617 ansi protection functions line differential protection, stabilized low stage and instantaneous high stage lnpldf 3∆i...

  • Page 32

    Abb oy distribution automation p.O. Box fi-101 vaasa, finland phone +8 10 11 fax +8 10 10 www.Abb.Com/substationautomation 1mrs756500 a © copyright 2008 abb. All rights r eserved..