Abus RM20 User Manual - page 5
– 16 –
– 17 –
CoMMISSIoNING
First of all, remove any activation
safeguards(e.g.acotterpin)and
make sure that the activation safe-
guard does not get into the device!
Then press the device’s activation
button(Fig.1,I.)whichisshownin
thepictureonpage15.Afterthe
button has been pushed in, it must
beflushwiththeunit’shousing.If
the smoke alarm has been activated
successfully, a brief test tone sounds
toconfirmactivation.Thistesttone
will also sound when you press the
testandstopbutton(Fig.1,IV)to
verify that the unit is operating
correctly.
FUNCTIoN
The heat alarm function is activated
under the following conditions:
• When the temperature is over 40°C
and rises by more than 4°C in
80 seconds
• If the temperature exceeds 60°C for
more than 8 seconds
• Heat alarm tone: single beep, once
a second
• Smoke alarm tone: double beep,
once a second
CHooSING A LoCATIoN
Bedroom
Kitchen
Living room
Boiler room
Workshop
room
Children’s
room
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
RM
Bedroom
Bathroom
Kitchen
Living room
Children’s
room
Children’s
room
RM
RM
RM
RM
RM
RM
Fig.2
390371_MoAnltg RM 20_D_GB_F_NL_I_11.2012.indd 16
14.11.12 13:16