• Serial number
• Firmware version
• MAC address / IP address / Netmask / Gateway of LAN interface
• Server’s power state
The following actions can be initiated via SNMP:
• Reset server
• Power on/off server
• Reset the ARMC/3P
The following events are reported by the ARMC/3P via SNMP:
• Login trial at the ARMC/3P failed.
• Login trial at the ARMC/3P succeeded.
• Denying access to a particular action.
• Server was reset.
• Server was powered on/off.
Figure 89 SNMP Settings
The SNMP settings panel as shown in Figure 89 is described below. It allows you
to change SNMP related parameters.
Enable SNMP Agent
If this option is checked, the ARMC/3P will answer to SNMP requests.
Important: If a community is left blank, you cannot perform the
according request. E.g. if you want to disable the possibility to
reset the ARMC/3P via SNMP then do not set a write community.