3.4.2 Reset to Factory Defaults Using the Remote Input
Eight-pulse the remote input to apply the factory defaults and return to Run mode.
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
NOTE: The input wire function remains at remote teach input (
).
3.5 Locking and Unlocking the Sensor Buttons
Use the lock and unlock feature to prevent unauthorized or accidental programming changes. When locked,
displays when the (SELECT)(TEACH) button is pressed. The switch point displays when (+)(LO/DO) or (-)(MODE) are
pressed, but
displays if the buttons are pressed and held.
Button Instructions
To lock or unlock the sensor using the buttons, press and hold
and press
four times.
or
flashes,
depending on the previous status.
Remote Input Instructions
1. Access the remote input.
Action
Result
Four-pulse the remote input.
T
T
T
T
T
T
T
The sensor is ready to have the button
state defined and
displays.
2. Lock or unlock the sensor buttons.
Action
Result
Single-pulse the remote input to unlock the sensor.
T
displays and the sensor returns to
Run mode.
Double-pulse the remote input to lock the sensor.
T
T
T
displays and the sensor returns to
Run mode.
3.6 TEACH Procedures
Use the following procedures to teach the sensor.
To cancel a TEACH procedure, press TEACH for longer than 2 seconds, or hold the remote input low for longer than 2
seconds.
momentarily displays when a TEACH procedure is canceled.
3.6.1 Two-Point Static Background Suppression TEACH
Two-point TEACH sets a single switch point. The sensor sets the switch point between two taught target distances, relative
to the shifted origin location.
Q4X Stainless Steel Laser Sensor