BullFrog Spas Owner's Manual - page 12
Page 12
Bullfrog Spas Owner’s Manual
INITIAL START-UP
Important: Bullfrog Spas come with either an
Economy, Deluxe or Premium Control System. Refer
only to the Control System that applies to your spa.
ECONOMY CONTROL SYSTEM:
Turn on the circuit breaker. Your spa will start up
automatically and will heat to 100°F (38°C) if no other
temperature is set. Depending on the outside ambient
temperature, your spa will heat at the rate of .5-1° per
hour for 120 Volt systems and between 5-10° per hour
for 240 Volt systems.
One minute after start-up, the spa will begin a 4-hour
filter cycle to clean the water. To select a different
duration, see "Preset Filter cycles" under “Operation”.
DELUXE CONTROL SYSTEM:
Turn on the circuit breaker. Your spa will start up
automatically and will heat to 100°F (38°C) if no other
temperature is set. When your spa is first actuated it
will start up in the Economy Mode and the LCD will
alternately flash “Econ”, the current spa temperature,
and “COOL” until the spa water is less than 15°F cooler
than the set temperature. During each filter cycle, the
spa will heat to the set temperature. Depending on the
outside ambient temperature, your 240 Volt spa will
heat at the rate of 5-10° per hour.
One minute after start-up, the spa will begin a four
hour filter cycle to clean the water. To select a
different duration, see " Preset Filter cycles" under
“Operation”.
PREMIUM CONTROL SYSTEM:
Turn on the circuit breaker. Your spa will start up
automatically and will be in the Economy Mode. Simply
press the “#” button to switch the spa to the Standard
Mode and begin heating. The spa will heat to 100°F
(38°C) if no other temperature is set. Depending on
the outside ambient temperature, your 240 Volt spa
will heat at the rate of 5-10° per hour.
Time of Day: You will see the words “set time”
flashing on the display. To set the time, press the
“Time” button then the “*” button then the “Warmer” or
“Cooler” button. After either button is pressed once,
the time will begin changing in one-minute
increments. Press either button to stop the time from
changing. Press the “#” button to enter your correct
time into the system.
Now that the time has been set correctly, your spa will
automatically filter itself for a 2-hour period every 12
hours. For average use, a 4-hour filter cycle is
recommended. To select a different duration, see
“Filter Cycles” under “Operation”.
Note: If the spa does not activate after turning on the
circuit breaker, it may be necessary to press the
"Reset Button" on the GFCI breaker.