LIGHT BULB REPLACEMENT
To replace a burned out or defective light bulb,
complete the following steps:
1. Disconnect electrical power supply.
2. Remove the door to the Equipment Compartment.
3. Locate the back of the Spa Light Fixture (Fig. X).
4. Grasp the light bulb holder located on the back of
the Spa Light Fixture. Twist counter-clockwise to
release it from Spa Light Fixture. Pull light bulb holder
out of Spa Light Fixture.
5. Replace light bulb and reinstall light bulb holder
into Spa Light Fixture.
6. Replace door to Equipment Compartment.
7. Restore electrical power supply.
OZONE STERILIZER
REPLACEMENT
On the front of your Bullfrog Ozone Sterilizer
(optional) is an ozone indicator light (the Ozone
Sterilzer is located in the equipment compartment).
This indicator light will glow whenever ozone is being
produced.
To verify that your Ozone Sterilizer is working
properly, check the indicator light when the filter
pump is running and only during a preprogrammed
filter cycle, making sure that the indicator light glows
(do not check the indicator light if you have activated
the jets within the previous 30 minutes - as a safety
device, your Ozone Sterilizer shuts down for 30
minutes after the “Jets” button has been pressed).
If the indicator light does not glow when the filter
pump is running then your Sterilizer is not working
properly. When this occurs, take the following steps:
1. Disconnect electrical power supply.
2. Locate the Ozone Sterilizer (Fig. Y).
3. Unplug the Ozone Sterilizer's power supply cord
from your spa's Control Center.
4. Disconnect the grounding wire from the Ozone
Sterilizer.
5. Disconnect the output tubing from the Ozone
Sterilizer.
6. Remove the mounting screws that hold the Ozone
Sterilizer in place.
7.Take the entire Ozone Sterilizer to your authorized
Bullfrog Portable Spa Dealer. Your Ozone Sterilizer will
be checked to verify that it is defective. If defective,
then replace the entire Ozone Sterilizer with a new
one.
Note: If your Ozone Sterilizer is found to be working
properly, then you may have a problem with your
spa's Control Center or Control Pad. Consult your
dealer and request a service call.
8. Reinstall the Ozone Sterilizer by reversing the
above procedure.