Cabletron Systems MRXI-22 User Manual - Power Supply Requirements
INSTALLATION REQUIREMENTS/SPECIFICATIONS
2-14
RCV
(yellow):
Indicates that the repeater is receiving
a data packet on that segment.
CPU
(flashing green):
This LED alternates from red to green
during power up. After the boot is
complete, the LED flashes green. A
flashing green LED indicates normal
operation. A red LED indicates a fault
in the processor.
POWER SUPPLY REQUIREMENTS
Note: The MRXI has a universal power supply. This unit allows you to use
an input power from 85 to 264 VAC, 47-63 Hz.
Parameter
Typical
Worst
Value
Case
Input Current:
0.5 A
0.75 A
Overload Protection - Output:
(1) 2AG 1 amp fuse.
ENVIRONMENTAL REQUIREMENTS
Operating Temperature:
+5
°
to +50
°
C
Non-operating Temperature: -30
°
to +90
°
C
Operating Humidity:
5 to 95% (non-condensing)
SAFETY
Designed in accordance with UL478, UL910, NEC 725-2(b), CSA,
IEC, TUV, VDE class A. Meets FCC part 15, Class A limits.
Warning: It is the responsibility of the person who sells the system to
which the MRXI will be a part to ensure that the total system meets