Cabletron Systems MRXI-22 User Manual - 3.5.3
INSTALLATION
3-10
d. Check that the twisted pair connection meets dB loss and cable
specifications outlined in 10BASE-T Twisted Pair Network
Requirements.
e.
Check that the cross-over switch is in the correct position.
Figure 3-11
Cable Pin-outs - EPIM-T RJ-45 Port
If a link still has not been established, contact Cabletron Systems
Technical Support.
3.5.3
Connecting an AUI Cable to an EPIM-X
To connect an EPIM-X to an external network device, attach an AUI
cable, no longer than 50 meters in length, to the port located on the
EPIM-X. See Figure 3-12. You must also set the SQE switch to off.
CAUTION: Ensure that the external transceiver to which the MRXI will be
connected does not have the signal quality error (SQE or “heartbeat”) test
function enabled. The MRXI will not operate if the transceiver has the
SQE test function enabled, and the network will be unusable. Refer to the
applicable transceiver manual.
1
2
3
6
1
2
3
6
RJ-45 to RJ-45
EPIM-T
Port
10BASE-T Device
Port
RX+
RX-
TX+
TX-
TX+
TX-
RX+
RX-
NOTE:
RX+/RX- and TX+/TX-
must share a common
color pair.