Parts list circuit diagrams
2.15.1 Room temperature sensor (optional)
2.15.9 External temperature sensor (optional)
3.1.7 ”OFF“
pushbutton
3.1.9 ”Heat / ventilate“ switch
3.1.11 ”Round“ control unit
3.2.15 EasyStart T timer
3.3.9 EasyStart R radio remote control (stationary unit)
3.8.3 Antenna
a)
Connection of control units at the heater
c)
Terminal 58 (lighting)
d)
Parking ventilation with vehicle blower (optional)
e)
EasyStart T timer connection
g)
External ”ON / OFF“ button (optional)
y)
Connect and insulate cables
The radio remote control must be connected as shown in
the circuit diagrams at the end of the installation instruc-
tions.
Note heater type!
Insulate unused cable ends.
Connectors and contact housings are shown from the
cable inlet side.
Cable colours
sw = black
ws = white
rt = red
ge = yellow
gn = green
Circuit diagrams
vi = violet
br = brown
gr = grey
bl = blue
li =
purple
Please note!
Allocation of the circuit diagrams for AIRTRONIC
heaters
The circuit diagrams are allocated via the installed control
box:
• Control box with 2 diagnosis cables and JE diagnosis.
The diagnosis cable bl/ws is connected to chamber
3 of the 16 pin connector, diagnosis cable bl/ge is
connected to chamber 8.
• Control box with diagnosis cable:
The diagnosis cable bl/ws is connected to chamber 8
of the 16 pin connector.