Eberspächer EasyStart Remote Technical Documentation Manual - page 8
8 | VEHICLE HEATERS – TECHNICAL DOCUMENTATION
2 INSTALLATION
INSTALLATION
The stationary unit is installed inside the
vehicle together with the button, the room
temperature sensor and the antenna.
INSTALL STATIONARY UNIT
Use the screws supplied to install the station-
ary unit in a dry place inside the vehicle, but
not near ventilation air outlets or directly next
to the fan motor.
INSTALL BUTTON
Install the button within the driver's view; the
preferred place for installation is the dash-
board.
Drill a hole ø 10 mm e.g. in the dashboard,
then clip in the button.
PLEASE NOTE!
Always install the button. The button LED is
used as the operating display.
INSTALLING THE ROOM TEMPERATURE
SENSOR
Use the screw provided to fasten the supplied
room temperature sensor inside the vehicle
so that it measures the representative interior
temperature.
Do not position the room temperature sen-
sor in an area in which is exposed to direct
sunlight, near the outlet vents of the vehicle or
in the footwell.
Recommendation:
The room temperature sensor should be
installed in the centre console at seat height.
PLEASE NOTE!
When installing the components ensure that
they are sufficiently clear of the airbags, so
that even if an airbag is triggered it cannot
come into contact with the components.
CONNECTING THE CONNECTOR HOUSING TO
THE STATIONARY UNIT
Attach the tab connector to the control unit
lead harness.
Clip the control unit lead harness, the room
temperature sensor lead harness and the
button lead harness into the 12-pin con-
nector housing (connector housing pin
assignment
see page 9
).
Push the contact locking device into the
connector housing.
Connect the 12-pin connector housing to
the stationary unit.
PLEASE NOTE!
When installing the connector, ensure that the
locking tangs always face the middle of the
connector. Only in this position to the tangs
latch into the housing (see sketch).