14
P0016-LI-03.01
Telephone Line Connections
The control panel has an advanced on-board communicator and
modem, which can be used for the following:
f
Sending digital alarm status information to an alarm
receiving centre using industry standard protocols
f
Sending voice messages to a mobile or landline telephone
f
Remote uploading/downloading via Eclipse UDL software
package
If any of these features are used, a permanent telephone
connection should be made to the control panel as shown:
In from telephone provider
Out to premises telephone
Control Panel
R1
T
R
T1
Commissioning
Once ALL connections have been made to the control panel and
power is ready to be applied, you should read this section before
continuing.
The control panel leaves the factory programmed with default
settings and when the system is powered up for the first time the
default settings are in use. If the factory defaults need to be
reloaded in the future, please see “Power-up Options Menu”.
f
Connect the black battery lead to the negative (–) terminal of
the standby battery and the red battery lead to the positive
(+) terminal of the standby battery. The green power LED on
the main PCB will light.
f
If the system enters into an alarm condition, enter the
default master user code
5678
. The alarm tone will
then stop.
f
To access the Engineer Programming Menu, enter the
default engineer code
1234
. The remote keypads will
show:
En
Engineers Menu
Location:----
LED
LCD
f
Confirm that all devices connected to the control panel are
being recognized; see “Confirm Devices” below.
f
Program the system as described in the next section
(Programming the Control Panel).
f
Carry out a walk test as described on page 42. Remember
that some powered detectors (e.g. PIRs and combined
technology detectors) take several minutes to warm up
before they become operational.
f
Test the internal sounder, external sounder and strobe as
described on page 42.
f
Replace the lid and secure with the lid screw supplied - do
not over-tighten.
f
Enter
*99
to leave the programming menus.
f
The Service light will be flashing to indicate that action is
required. Switch on the mains supply to the control panel.
The Service light will stop flashing and stay on continuously.
Installation is now complete and the system is ready for use.
Please ensure the system users are provided with adequate
training on operating the alarm system.
Confirm Devices
When the system is powered up, the devices connected to the
control panel network must be confirmed. If the network
configuration changes after confirmation, the system will show
“Confirm Devices”:
Key:
L=EC-LCD Keypad
7=EC- LED Keypad
E=EC-EX10 Expander
I=EC-EX10/I Expander
O
=EC-EX10/O Expander
Cd
Engineers Menu
Location:----
Keypads: L7--
Expanders: E--- O---
Enter Engineers code
????
Enter
98*
Press
to confirm
devices.
*
Confirm Devices
14:15 31/10/2011
En
22
No of keypads
No of Expanders
Power-Up Options Menu
When power is applied to the system, the control panel enables
the “Power-Up Options Menu” for 10 seconds. During this period
the control panel status LED flashes between red and green and
the system will accept the following commands:
Command Description
*0#
Default Engineer Code
Entering this command will set engineer access code
back to 1234.
*3#
Save as Factory Defaults
Entering this command will save the current control
panel program configuration as the NEW factory
default profile.
*6#
Set UDL Password
Entering this command will set the UDL password to
123456.
*9#
Load Factory Defaults
Entering this command will set all control panel
program configuration options to the factory default
settings.