Eclipse EC-P50 Installation Manual - page 28
28
P0016-LI-03.01
2 Lockout
Keypad
On: If the “Enable Code Tamper” option is enabled for the
selected keypad, the keypad operation will be locked out for
5 minutes if a code tamper event is generated.
Off: The selected keypad operation remains unchanged.
Keypad Sounds
This set of options controls how the selected keypad generates
sounds from its on-board sounder.
Locations:
4131
to
4136
Keypads 1 to 6: Sounds.
Entry Mode:
Bit Toggle Selection (see page 17).
1 Alarm
Tones
On: The selected keypad generates alarm tones.
Off: The selected keypad will not generate alarm tones.
2 Trouble
Tones
On: The selected keypad generates trouble tones.
Off: The selected keypad will not generate trouble tones.
3 Chime
Tones
On: The selected keypad generates chime tones.
Off: The selected keypad will not generate chime tones.
4 Entry
Tones
On: The selected keypad generates entry tones.
Off: The selected keypad will not generate entry tones.
5 Exit
Tones
On: The selected keypad generates exit tones.
Off: The selected keypad will not generate exit tones.
6
Key Press Tones
On: The selected keypad generates key press tones.
Off: The selected keypad generates a short click tone when keys
are pressed.
7 Advisory
Tones
On: The selected keypad generates advisory tones.
Off: The selected keypad will not generate advisory tones.
8 Tamper
Tones
On: The selected keypad generates tamper alarm tones.
Off: The selected keypad will not generate tamper alarm tones.
Keypad Areas
Keypads must be assigned to one or more areas to ensure correct
operation of the system. The keypad areas control the following:
f
When the system is exit mode only the keypads in the areas
that are being armed will generate the exit tone.
f
When arming one or more areas from a keypad, only the
arming modes for the area(s) that are assigned to keypad
are applied. The areas that are not assigned are armed
instantly. For example, if the keypad is assigned to area 2,
and a user request to arm all areas (1-5), areas 1, 3, 4 and 5
arm instantly and the exit mode for area 2 is applied e.g. 30
seconds exit delay.
f
When using a “Local Standard” user only the areas assigned
to keypad can be armed and disarmed.
f
When a lid tamper is activated from the keypad, the tamper
alarm is generated for the area(s) assigned to keypad.
Locations:
4141
to
4146
Keypads 1 to 6: Areas.
Entry Mode:
Bit Toggle Selection (see page 17).
1 Area
1
On: The keypad is assigned to area 1.
Off: The keypad is not assigned to area 1.
2 Area
2
On: The keypad is assigned to area 2.
Off: The keypad is not assigned to area 2.
3 Area
3
On: The keypad is assigned to area 3.
Off: The keypad is not assigned to area 3.
4 Area
4
On: The keypad is assigned to area 4.
Off: The keypad is not assigned to area 4.
5 Area
5
On: The keypad is assigned to area 5.
Off: The keypad is not assigned to area 5.