Panel Output Areas
This set of options allows the output areas to be assigned to each
of the control panel high current outputs.
Locations:
6131
to
6135
Panel Outputs 1 to 5: Output Areas.
Entry Mode:
Bit Toggle Selection (see page 17).
1 Area
1
On: The panel output is assigned to area 1.
Off: The panel output is not assigned to area 1.
2 Area
2
On: The panel output is assigned to area 2.
Off: The panel output is not assigned to area 2.
3 Area
3
On: The panel output is assigned to area 3.
Off: The panel output is not assigned to area 3.
4 Area
4
On: The panel output is assigned to area 4.
Off: The panel output is not assigned to area 4.
5 Area
5
On: The panel output is assigned to area 5.
Off: The panel output is not assigned to area 5.
Output Types
The output types are grouped together in the following groups:
Group Description
00 Global
Global system output function.
01 Reserved
Not available on the EC-P50.
02 Control
Timer
Control Timers 1 to 5.
03 Remote
Control
Remote control outputs 1 to 5.
04 Link
Control
Input linked logical conditioned outputs.
10 Zone
Count
Zones 1 to 50 count outputs.
20 Zone
Mimic
Zones 1 to 50 mimic outputs.
30 Zone
Alarm
Zones 1 to 50 alarm outputs.
40 Zone
Tamper
Zones 1 to 50 tamper alarm outputs.
50 Zone
Masked
Zones 1 to 50 masked outputs.
60 Zone
Fault
Zones 1 to 50 fault outputs.
70 Zone
Bypassed
Zones 1 to 50 bypassed outputs.
80 User
Access
Users 00 to 50 access outputs.
00: Global
The table below list the output function available in this group:
No
Type & Description
0000 Not
Used
This output type does not activate.
0001 AC
Fault
This output type activates when the mains supply has been
removed for the duration of the AC Fail timer.
No
Type & Description
0002 ATS
Fault
This output type activates when the on-board communicator
detects a phone line fault (Alarm Transmission Fault).
0003 Unset
This output type activates when the system is in the
disarmed state.
0004 Armed
This output type activates when the system is armed in any
of the armed modes (Away or Stay)
0005 Part
Armed
This output type activates when the system is armed in any
of the Stay armed modes.
0006 Armed/Alarm
This output type activates when the system is armed and
pulses when an alarm is generated.
0007 Bell
Active
This output type activates when an alarm is generated (it
may be delayed if the bell delay time is greater than zero).
The duration of this output type is controlled by the “Bell
Duration” timer.
0008 Strobe
Active
This output type activates when an alarm is generated and
deactivates when the system is reset
0009 Alarm
This output type activates when an intruder alarm is
generated.
0010 Confirmed
Alarm
This output type activates when two different zones cause
an intruder alarm.
0011 Alarm
Abort
This output type activates when the user disarms the system
after an alarm and within the “Abort Delay” period.
0012 Fire
Alarm
This output type activates when a fire alarm is generated.
0013 PA
Alarm
This output type activates when a panic alarm is generated.
0014 Duress
Alarm
This output type activates when a duress alarm is generated.
0015 24hr
Alarm
This output type activates when a 24hr alarm is generated.
0016 Medical
Alarm
This output type activates when a medical alarm is
generated.
0017 Tamper
Alarm
This output type activates when a tamper alarm is
generated.
0018 Ready
This output type activates when the system is ready for
arming, i.e. all zones are healthy.
0019 Trouble
This output type activates when a trouble alarm is
generated.
0020 Alert
This output type activates when an alert event is generated
and deactivates when the user has acknowledged the alert.
0021 Zone
Bypass
This output type activates when one or more zones are
bypassed.
0022
In Walk Test
This output type activates when the user walk test mode is
selected.
0023
Flash 1 Second
This output type continually pulses on and off at a rate of 1
second.
0024
User Test Active
This output type activates when the user test mode is
selected in the “Bell Test” menu.