Eddyfi Reddy User Manual - page 50
36 | www.eddyfi.com
Using Reddy with Sharck Probes
7. Tap Next.
8. Configure the encoder and the starting position.
Note
Apart from the
Preset value, you should not modify any of the encoder parameters because they
are already optimum for the Sharck probe.
Figure 5–17 Scan definition: configure encoder and start position
9. Tap Next.
10. In Data Definition, adjust the properties of your filters.
Figure 5–18 Data definition: configuring filters
Notes
• Sharck probe setups are tailored for carbon steel. That is why you cannot change the frequencies
and injection voltages of these setups. Moreover, as most channel groups are necessary for
analysis, you can only disable the transverse group.
• We strongly recommended that you do not modify the median filter value, as it is configured to
detect and size 25 mm long defects in C-scan short.
11. Tap Next.
12. In Indication Codes, create the indication code list you wish to use during your analysis.