Fadini Junior 633 Instruction Manual - page 12
pag 19
Keyed selector:
Photocells and
safety edges:
1
DIP-SWITCH 1:
ON: stopped in opening and inverts in
closing or with obstacle removed
OFF: not stopped in opening and inverts in
closing or in presence of obstacle
Output for a possible automation status warning lamp
Warning Lamp On = Gate Open
Warning Lamp Off = Gate Closed
Flashing at 0.5s (rapid)= closing movement
Flashing at 1s (normal)= opening movement
Flashing at 2s (slow)= automation stopped
24V- 1W Warning
Lamp Output:
Radio contact:
connecting any contact NA between the two
terminals one may obtain upon each impulse:
- Only opening: Dip 2=ON e Dip 5=OFF
- Reverse direction on each impulse
Dip 2=OFF e Dip 5=OFF
- Step by step: Open-Stop-Close-Stop
Dip 2=OFF e Dip 5=ON
ON:
does not reverse and does not stop in opening
OFF: In oopening always stops and inverts
2
ON: Step by step with intermediate stop
OFF:
Reverses direction on every impulse contemporaneously ON
5
DIP-SWITCH 2 e 5 (MUST NOT ever be ON at
the same time):
All of the NC contacts for the safety
accessories such as photocells (receivers)
and edges must be connected in series to
terminals 1 and 2.
ELECTRICAL CONNECTIONS TO THE TERMINALS AND THEIR FUNCTIONS
Accessory
Electrical connctions
Dip - Switch and LED signals for the different function
NO and NC contacts to be connected to their
respective terminal boards or button panels.
All of the possible configurations are attached
to their respective command accessories
FA
D IN
I
Output 24V:
FA
D IN
I
FA
D IN
I
Astro 43
FA
D IN
I
NC
NC
1 2
3 4 5 6
NC
OPEN
CLOSE
ST
OP
COMMON
RADIO
CONTACT
COMMON
3
7
10
9
+ -
OUTPUT 24V for max load:
2 pairs of photocells
1 Radio receiver
1 LED selector Chis 37 / Chis E37
All of the instructions are attached to their
respective command accessories
L2 ON= No obstacle present, it turns off off
with obstacle present
L4 OFF= no contact open, it lights up with
each opening impulse
L5 OFF= no contact close, it lights up with
each closing impulse
L6 ON= STOP contact closed, goes on at
each stop contact
L7 OFF= no contact radio, it lights up with
each radio contact impulse
FADINI
FA
D IN
I
13 14
-
+
Output 24V cc/ca
for DSA control:
24V Output to power the photocell transmitters
(connected in parallel) for the DSA Control:
Autotest Safety Device = before each movement of
the gate, if this function is enabled, there is check of
all of the safety devices because they are free, in the
event that this is not so, the gate will not start up.
ON:DSA control of the photocells
OFF: No DSA control on the photocells
10
DIP-SWITCH 10
TX
FADINI
TX
meccanica
FADINI
Elpro 63
GB
Junior 633 - Junior 650
8 9
-
+