Jandy AquaLink RS Installation manual - page 20
20
All Button Control Panel Reset and Display Messages
Reviewing:
To review equipment, press the MENU button, then use the FORWARD arrow to scroll to the REVIEW menu. Press ENTER,
use the arrows to scroll to the item you wish to review, and press ENTER again.
Canceling Items:
If you make a mistake in programming or you want to change, for example, the ON/OFF times for a specific device, you can
cancel programs for that piece of equipment. For example, to CANCEL A DIMMER, press the CANCELbutton; use the
forward and back buttons to advance to DIMMERS and press ENTER. The AquaLink RS display will prompt to select an Aux.
Press the button of the Auxiliary for which you want to cancel the dimmer.
If you want to cancel a JVA assignment, first press the CANCEL button (if no JVAs are assigned, you cannot use this
function). Use the FORWARD and BACK arrows to advance to JVA ASSIGNS and press ENTER. The AquaLink RS display
will read CLEANER JVA. Use the FORWARD and BACK arrows to toggle between JVAs to cancel. When the JVA
assignment that you want to cancel is displayed, press ENTER. The AquaLink display will read PRESS ENTER TO CANCEL
JVA ASSIGNMENT,
or CANCEL TO ABORT. Press ENTER to cancel the JVA assignment, or press CANCEL to abort.
Resetting the System:
To remove all labeling, programming, assignments, and temperature settings, press the MENU button, scroll to CLEAR
MEMORY and press ENTER twice.
Power Center Service Switch:
AUTO Mode (automatic):
The Controller has complete control of all functions. All programmed settings will operate. All safety delays and equipment
protection interlocks are operational.
SERVICE Mode:
The Power Center has complete control of all functions. Service Mode must be turned On/Off at the Power Center. No
programmed settings will operate. CAUTION: In service mode, the safety interlocks for equipment protection are overridden.
TIMEOUT Mode:
The Power Center has complete control for 3 hours. After 3 hours, the system will return to Auto Mode. Programmed On/Off
times will be overridden during the 3 hours. After the three hour "time-out", the system will resume any programmed times
that were overridden.
Battery Back-Up:
A nine-volt battery is located at the Power Center. Do not install battery in the Power Center until system is ready to operate.
Battery will drain if power is left off. Review DIAGNOSTICS in the SYSTEM SETUP section of the Menu. The DIAGNOSTICS
will indicate when the battery needs replacement.
Light Dimmer:
Dimmers can be set at 25%, 50%, 75% or 100%, depending upon the amount of light desired, by pressing the AUX assigned
as a dimmer and using the arrow
<—>*
buttons to dim or brighten. Once desired brightness is achieved, press ENTER.
Press AUX to turn off.
NOTE: When light is turned back on, it will automatically return to brightness last set.
From the Spa Side Switch or SpaLink RS, light dimming operates as follows:
When a button assigned to a light dimming auxiliary is pressed, the light will turn on at full brightness, and each press of
the button will decrease brightness 25% until light is off.
Special Note to "Start-up Person":
The AquaLink RS allows you two options for operating the pool equipment for the first day of operation:
Option #1 - Once all programming of equipment is completed, go to the Power Center Service Switch. Push the Switch
three times which moves from "AUTO" to "SERVICE" to "TIME-OUT" and finally back to "AUTO". The
AquaLink RS will now "look back" (review) all programs and turn on any equipment which is programmed to
be on. Close up system; it will now operate as programmed.
Option #2 - If you want the filter pump or cleaner to operate continually for the first day, leave the Power Center Service
Switch in "AUTO" mode. Go to the indoor controller and press the AUX buttons for the equipment you want
to run. The equipment activated will now run continuously, ignoring the first programmed off time, and turn
off at the programmed off time for the next day.