OneTouch Control Panel Reset and Display Messages
Resetting the System:
To remove all labeling, programming, assignments, and temperature settings, highlight MENU/HELP press select,
highlight SYSTEM SETUP press select, highlight CLEAR MEMORY and press select. Select CONTINUE, then select
either yes or no to clear memory. There will be a 15 second delay before you see the FINISHED screen, select
CONTINUE to return to SYSTEM SETUP.
Power Center Service Switch:
AUTO Mode (automatic):
The Controller has complete control of all functions. All programmed settings will operate. All safety delays and
equipment protection interlocks are operational.
SERVICE Mode:
The Power Center has complete control of all functions. Service Mode must be turned On/Off at the Power Center. No
programmed settings will operate. CAUTION: In service mode, the safety interlocks for equipment protection are
overridden.
TIMEOUT Mode:
The Power Center has complete control for 3 hours. After 3 hours, the system will return to Auto Mode. Programmed On/
Off times will be overridden during the 3 hours. After the three hour "time-out", the system will resume any programmed
times
that were overridden.
Battery Back-Up:
A nine-volt battery is located at the Power Center. Do not install battery in the Power Center until system is ready to
operate. Battery will drain if power is left off. Review DIAGNOSTICS in the SYSTEM SETUP section of the Menu. The
DIAGNOSTICS will indicate when the battery needs replacement. The battery will keep the clock running during power
outages.
Light Dimmer:
Dimmers can be set at 25%, 50%, 75% or 100%, depending upon the amount of light desired. Use the DIMMERS menu
under SYSTEM SETUP to assign an auxiliary to be dimmed. Note: you must install a light dimming relay.
From the Spa Side Switch or SpaLink RS, light dimming operates as follows:
When a button assigned to a light dimming auxiliary is pressed, the light will turn on at full brightness, and each press of
the button will decrease brightness 25% until light is off.
Special Note to "Start-up Person":
The AquaLink RS allows you two options for operating the pool equipment for the first day of operation:
Option #1 - Once all programming of equipment is completed, go to the Power Center Service Switch. Push the
Switch three times which moves from "AUTO" to "SERVICE" to "TIME-OUT" and finally back to "AUTO".
The AquaLink RS will now "look back" (review) all programs and turn on any equipment which is
programmed to be on. Close up system; it will now operate as programmed.
Option #2 - If you want the filter pump or cleaner to operate continually for the first day, leave the Power Center
Service Switch in "AUTO" mode. Go to the indoor control panel and highlight EQUIPMENT ON/OFF press
select, then select the equipment you want to run. The equipment activated will now run continuously,
ignoring the first programmed off time, and turn off at the programmed off time for the next day.