Jandy AquaLink RS Installation manual - page 28
28
AquaLink RS Troubleshooting
Quick Check List
Symptom
Problem
Possible Solution
System sometimes does not
run programmed on and off
times.
Power outage with dead
battery.
At Controller, check battery
level. With software level Rev. F
or newer, battery status is
located in Diagnostics section
of System Setup Menu.
One button on the Four Func-
tion Switch or SpaLink RS
does not operate.
Check programming first.
If the Four Function Switch or
SpaLink RS is programmed
correctly, the button may be
shorted.
Replace the Four Function
Remote or SpaLink RS.
Use MENU, REVIEW, SPA
SWITCH (or SPALINK) to
check programming
Pool cleaner booster pump
turns on without the filter pump
being on, and can run with the
spa on.
System is not recognizing
DIP Switch 1 is on.
NOTE: Before turning on any
DIP Switches, first turn off all
equipment.
Turn off all equipment buttons,
then turn off power to system,
finally turn off, then on, DIP
Switch 1. Turn on power and
test system.
Cannot assign Cleaner JVA.
DIP switches not set correctly.
DIP Switch 1 must be off, and
DIP Switch 7 must be on to
assign the Cleaner JVA to an
auxiliary (Rev F or older).
Model is one of the AquaLink RS
Dual Equipment, message scrolls
"Adjustable Freeze Sensor Not
Installed".
Normal operation when a Dual
Equipment AquaLink RS is
controlling a solar system and
an adjustable freeze sensor is
not installed.
Either install the adjustable
freeze sensor, or wait 24 hours
and this message will go away.
System comes on at times that
are not programmed.
Phantom programs.
At Controller press Menu, then
scroll, to REVIEW. Make note
of all programs, Four Function
Switch setting, labels, and
temperature settings, then turn
off all DIP switches and go to
the Controller. CLEAR
MEMORY, reprogram and try
system again.
Heater will not fire.
Heater LED will not light in
"Service Mode".
Water temperature sensor
not installed or defective.
Check water temperature
sensor.
®